User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 9
 Downloands 2
Doğal Polimer Destekli Bir Titanyum Nanokompozit Elektrodun Lizin Amino Aside Karşı Elektrokimyasal Duyarlılığı, Seçiciliği ve Duyusal Özellikleri
2023
Journal:  
Muş Alparslan Üniversitesi Fen Bilimleri Dergisi
Author:  
Abstract:

Bu çalışmada kitosan (Chit) destekli titanyum (Ti) nanoparçacıkları (Ti@Chit NPs) kimyasal yöntemle sentezlendi. Ti@Chit NP'leri taramalı elektron mikroskobu (SEM) ve atomik kuvvet mikroskobu (AFM) sonuçlarına göre sırasıyla 7,275 ± 2,15 nm ve 18,629 nm olarak hesaplanmıştır. Sentezlenen NP'ler elektroda modifiye edildi ve lizin amino aside karşı bir duyarlılık çalışması yapıldı. Ti@Chit elektrodunun amino asit lizine karşı katalitik bir performansa sahip olduğu belirlenmiştir. Tespit sınırı (LOD) değerinin ortalama 0,0041 µM olduğu tahmin edilmektedir.

Keywords:

Electrochemical Sensitivity, Selectivity, and Sensory Properties Of A Natural Polymer-supported Titanium Nanocomposite Electrode Towards Lysine Amino Acid
2023
Author:  
Abstract:

In this study, chitosan (Chit) supported titanium (Ti) nanoparticles (Ti@Chit NPs) were synthesized by chemical method. Ti@Chit NPs were calculated to be 7.275 ± 2.15 nm and 18.629 nm according to scanning electron microscopy (SEM) and atomic force microscopy (AFM) results, respectively. The synthesized NPs were modified to the electrode and a sensitivity study was carried out against lysine amino acid. It has been determined that the Ti@Chit electrode has a catalytic performance against the amino acid lysine. The limit of detection (LOD) value is estimated to average 0.0041 µM.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Muş Alparslan Üniversitesi Fen Bilimleri Dergisi

Field :   Fen Bilimleri ve Matematik; Mühendislik; Ziraat, Orman ve Su Ürünleri

Journal Type :   Uluslararası

Metrics
Article : 140
Cite : 181
© 2015-2024 Sobiad Citation Index