User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 14
İki Aşamalı Organik Rankine Çevriminde Farklı Soğutucu Akışkan Kullanımının Sistem Performansına Etkisi
2021
Journal:  
Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
Author:  
Abstract:

Bu çalışmada mühendislik denklem çözücü program (Engineering Equation Solver - EES) kullanılarak iki kademeli bir Organik Rankine Çevriminin (ORC) enerji analizi yapılmıştır. Birinci ve ikinci kademelerde sekiz farklı organik akışkan (R134a, R410a, RC318, R407c, R22, R23, R116 ve R218) çiftler halinde belirli sıcaklık limitleri arasında kullanılmıştır. ORC’nin yüksek ısıl verim ve net iş çıktısı için uygun bir soğutucu akışkan veya soğutucu akışkan çifti seçimi yapmak çok önemlidir. Bu çalışmanın amacı, çevrim akışkanının sistem verimine etkisini belirlemek ve en uygun akışkan çiftini bulmaktır. Sonuçlar, en yüksek net güç çıkışının ve en yüksek termal verimin R23+R23 çiftinden elde edildiğini göstermektedir. Ayrıca en düşük net güç çıkışının RC318+RC318 çiftinden ve en düşük termal verimin ise R218+R218 çiftinden elde edildiği gözlemlenmiştir

Keywords:

The Effect Of Using Different Refrigerants On System Performance In Two-stage Organic Rankine Cycle
2021
Author:  
Abstract:

In this study, energy analysis of a double-stage Organic Rankine Cycle (ORC) was performed using the Engineering Equation Solver program (EES). In the first and second stages, eight different organic working fluids (R134a, R410a, RC318, R407c, R22, R23, R116, and R218) were used in pairs for certain temperature limits. Choosing a suitable refrigerant or refrigerant pair is crucial for the ORC’s high thermal efficiency and net work output value. This study aims to determine the effect of working fluid on system efficiency and find out the most suitable working fluid pair. The results showed that the highest net power output and the highest thermal efficiency were obtained from the R23+R23 pair. It was also observed that the lowest net power output from the RC318+RC318 pair and the lowest thermal efficiency was obtained from the R218+R218 pair.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Çukurova Üniversitesi Mühendislik Fakültesi Dergisi

Field :   Mühendislik

Journal Type :   Ulusal

Metrics
Article : 1.001
Cite : 1.665
Çukurova Üniversitesi Mühendislik Fakültesi Dergisi