User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 11
 Downloands 3
Effect of evaporator-condenser diameter ratio (d/D) on thermal performance of the tapering heat pipe with various heat sources
2018
Journal:  
Eastern-European Journal of Enterprise Technologies
Author:  
Abstract:

In the present study, a new tapering heat pipe design had been developed to enhance the thermal performances. Boiling visualization in the tapering heat pipe is investigated to provide the detailed information of bubbles nucleation. Experiment was conducted in the tapering heat pipe with variation of the evaporator (d) to condenser (D) diameter ratio. The values of d/D are varied at 1/1; 1/2; 1/3 and 1/4. Heat load was generated at the evaporator section using heater DC-Power supply at 30, 40 and 50 Watt. The visualization technique was developed by using a transparent glass tube and the images of boiling bubbles were captured by SLR camera. The glass tube inclination is 45° and integrated with the NI-9211 and c-DAQ 9271 module. K-type thermocouple was set at the evaporator and condenser sections for measurement of boiling temperatures in the tapering heat pipe. Based on the results, it can be noted that variations of heat load and diameter ratio (d/D) of the evaporator and condenser affect the size and shape of boiling bubbles, as well as the nucleation temperature on the tapering heat pipe. The heat transfer coefficient tends to increase at a heat load of 50 W and diameter ratio d/D=1/4. Author Biographies Sarip Sarip, Ronggolawe Technology High School Jalan. Campus Ronggolawe Blok B/I, Cepu, Indonesia, 58312 Doctoral Student Department of Mechanical Engineering

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Eastern-European Journal of Enterprise Technologies

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 4.764
Cite : 4.484
Eastern-European Journal of Enterprise Technologies