User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 19
 Downloands 2
Preconcentration of Trace Elements on Amberlite XAD-4 Resin Functionalised with 1,2-bis (o-aminophenylthio) Ethane and Their Determination by FAAS in Environmental Samples
2007
Journal:  
Turkish Journal of Chemistry
Author:  
Abstract:

The use of chemically modified XAD-4-1,2-bis (o-aminophenylthio) ethane chelating resin for preconcentrating Cr6+, Mn2+, Fe3+, Co2+, Cu2+, Cd2+, Zn2+, Pb2+, and Ni2+ was studied using flame atomic absorption spectrometry (FAAS) for metal monitoring in environmental samples. Cd2+, Zn2+, Pb2+, and Ni2+ ions were quantitatively recovered at the rate of 96.0%, 101.0%, 101.0%, and 95.0%, respectively (RSD < 5%), from the studied solutions. The procedure is based on the retention of analytes on a short column of 1,2-bis (o-aminophenylthio) ethane-XAD-4 chelating resin from a buffered sample solution and subsequent elution with 1 M HNO3. Various parameters, such as pH, eluent type, and concentration, flow rate of sample solution and matrix interference effect on the retention of the metal ions have been studied. The optimum pH for the sorption of the above-mentioned metal ions was about 6. The adsorption and batch capacity of adsorbent and loading half time (t1/2) for Ni2+, Zn2+, Cd2+, and Pb2+ were established. The limit of detection was 3.0 m g L-1 for Pb2+ and Ni2+, 0.6 m g L-1 for Cd2+, and 0.3 m g L-1 for Zn2+. The validation of the procedure was carried out by analysis of certified reference materials and standard addition. The proposed enrichment method was applied to environmental samples from Trabzon.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Turkish Journal of Chemistry

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 2.410
Cite : 1.547
Turkish Journal of Chemistry