User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 11
 Downloands 4
The importance of background correction during calculation of the major salivary gland function in salivary gland scintigraphy
2015
Journal:  
Dicle Tıp Dergisi
Author:  
Abstract:

Objective: The aim of this study was to compare the parotid (P) and submandibular (SM) glands uptake and excretion ratios of 99mTc-pertechnetate, which were calculated by using the backgrounds drawn on five different areas. Methods: Ninety-eight P and 98 SM glands of totally 48 patients were included in the study. 99mTc-pertechnetate salivary gland scintigraphy was performed in all patients. Oral stimulation with lemon juice was made at 15th minute of the imaging. The 99mTc-pertechnetate uptake and excretion ratios of the P and SM glands were calculated separately without using any background, and by using the backgrounds drawn on wide frontal, narrow frontal, temporal, cervical and shoulder regions. These values were statistically compared with each other in pairwise manner. Results: The radioactivity uptake and excretion ratios of the P and SM glands calculated without using any background correction were statistically different from that calculated by using any background correction. In addition, the radioactivity uptake and excretion ratios of the P and SM glands calculated by using the backgrounds drawn on five different areas were mostly found statistically different from each other (p<0.05). Conclusion: Background correction is important during the calculation of the uptake and excretion ratios of P and SM glands. This study demonstrates that calculated uptake and excretion ratios of P and SM glands may differ according to the used background area. Key words: Salivary gland scintigraphy, parotid gland, submandibular gland, salivary gland function, background correction

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Dicle Tıp Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 1.608
Cite : 2.993
Dicle Tıp Dergisi