User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 16
 Downloands 5
Karışık taşınım ile olan ısı transferinin farklı geometrideki akış engelleri kullanılarak iyileştirilmesinin sayısal olarak incelenmesi
2023
Journal:  
Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi
Author:  
Abstract:

Bu çalışmada içinde ısı akısına sahip, farklı konum ve geometride engeller bulunan dik bir kanaldaki karışık konveksiyonun ısı transferine ve akış özelliklerine etkisi sayısal olarak incelenmiştir. Engellerin konumları, sayıları ve geometrileri değiştirilerek ısı transferine ve akış özelliklerine etkisi belirlenmeye çalışılmıştır. Çalışmada, alt alta bulunan iki yarı silindirik engelin, alt alta ve karşılıklı bulunan dört yarı silindirik engelin ve alt alta ve karşılıklı bulunan dört dikdörtgen engelin karışık konveksiyonla olan akış ve ısı transferine etkileri irdelenmiştir. Sonuç olarak Nusselt sayısının, engellerin birbirine olan uzaklıklarının (L/D oranı) ve doğal taşınım etkilerinin (Ri sayısı) artmasıyla genel olarak arttığı tespit edilmiştir. Her iki engel geometrisinde (yarı silindirik engel ve dikdörtgen engel) L/D oranının ve değiştirilmiş Ri sayısının arttırılmasının Nusselt sayısına olan etkisinin benzer olduğu ve ısı transferini arttırdığı tespit edilmiştir. Yarı silindirik engeldeki Nusselt değerlerinin dikdörtgen engeldeki Nusselt değerlerine kıyasla daha büyük olduğu belirlenmiştir. Yarı silindirik engeldeki Nusselt değerlerinin dikdörtgen engeldeki Nusselt değerlerinden farkının engeller arası mesafenin az olduğu (L/D=0,25) değer için düşük Ri sayılarında (Ri=50) %72,5 iken yüksek Ri sayılarında (Ri=200) %19,6 olduğu tespit edilmiştir. Bu fark engeller arası mesafenin çok olduğu (L/D=1,5) değer için düşük Ri sayılarında (Ri=50) %58,6 iken yüksek Ri sayılarında (Ri=200) %39,1 olduğu tespit edilmiştir. Her iki engel geometrisinde de en yüksek Nu sayısının L/D= 1,5 ve Ri=200 olduğu durumda meydana geldiği belirlenmiştir. Ayrıca çalışmada Nu sayısı için bir korelasyon elde edilmiştir. Sayısal çalışmanın sonuçları literatürde bulunan deneysel çalışmalarla da karşılaştırılarak sıcaklık dağılımını ve akış özelliklerini iyi şekilde temsil edebildiği görülmüştür.

Keywords:

Numerical study of the improvement of the heat transfer by mixed transfer using flow barriers in different geometers
2023
Author:  
Abstract:

In this study, the impact of the mixed convection on the heat transfer and flow characteristics in a straight channel with different locations and geometry barriers has been numerically studied. The locations, numbers and geometries of the barriers have been altered to determine the impact on the heat transfer and flow characteristics. In the study, the effects of the flow and heat transfer of the two semi-cylindrical barriers found under the bottom, the four semi-cylindrical barriers found under the bottom and the four rectangular barriers found under the bottom and the rectangular barriers found under the bottom and the rectangular barriers found under the bottom and the rectangular barriers found under the bottom. As a result, it has been found that the number of Nusselts has increased in general with the increase in the distance between barriers (L/D ratio) and the effects of natural transportation (Ri number). In the geometry of both obstacles (half-cylindrical obstacle and straight-cylindrical obstacle) the effect of the L/D ratio and the increase in the modified Ri number is similar to the Nusselt number and increases the heat transfer. The Nusselt values in the semi-cylindrical barrier were determined to be greater than the Nusselt values in the straight-cylindrical barrier. The difference between the Nusselt values in the semi-cylindrical barrier and the Nusselt values in the straight barrier; for the value that the gap between the barrier is less (L/D=0.25); for the low Ri numbers (Ri=50) is 72.5%, while for the high Ri numbers (Ri=200) is 19.6%. This difference was found for the value that the distance between barriers is much (L/D=1.5); the low Ri numbers (Ri=50) are 58.6%, while the high Ri numbers (Ri=200) are 39.1%. In the geometry of both obstacles, the highest number of Nu is L/D=1.5 and Ri=200. In addition; a correlation for the number of Nu was obtained in the study. The results of the numerical study, compared with the experimental studies in literature, have been shown to be able to well represent the temperature distribution and flow characteristics.

Keywords:

0
2023
Author:  
Abstract:

Bu çalışmada; içinde ısı akısına sahip, farklı konum ve geometride engeller bulunan dik bir kanaldaki karışık konveksiyonun ısı transferine ve akış özelliklerine etkisi sayısal olarak incelenmiştir. Engellerin konumları, sayıları ve geometrileri değiştirilerek ısı transferine ve akış özelliklerine etkisi belirlenmeye çalışılmıştır. Çalışmada, alt alta bulunan iki yarı silindirik engelin, alt alta ve karşılıklı bulunan dört yarı silindirik engelin ve alt alta ve karşılıklı bulunan dört dikdörtgen engelin karışık konveksiyonla olan akış ve ısı transferine etkileri irdelenmiştir. Sonuç olarak; Nusselt sayısının, engellerin birbirine olan uzaklıklarının (L/D oranı) ve doğal taşınım etkilerinin (Ri sayısı) artmasıyla genel olarak arttığı tespit edilmiştir. Her iki engel geometrisinde (yarı silindirik engel ve dikdörtgen engel) L/D oranının ve değiştirilmiş Ri sayısının arttırılmasının Nusselt sayısına olan etkisinin benzer olduğu ve ısı transferini arttırdığı tespit edilmiştir. Yarı silindirik engeldeki Nusselt değerlerinin dikdörtgen engeldeki Nusselt değerlerine kıyasla daha büyük olduğu belirlenmiştir. Yarı silindirik engeldeki Nusselt değerlerinin dikdörtgen engeldeki Nusselt değerlerinden farkının; engeller arası mesafenin az olduğu (L/D=0,25) değer için; düşük Ri sayılarında (Ri=50) %72,5 iken yüksek Ri sayılarında (Ri=200) %19,6 olduğu tespit edilmiştir. Bu fark; engeller arası mesafenin çok olduğu (L/D=1,5) değer için; düşük Ri sayılarında (Ri=50) %58,6 iken yüksek Ri sayılarında (Ri=200) %39,1 olduğu tespit edilmiştir. Her iki engel geometrisinde de en yüksek Nu sayısının L/D= 1,5 ve Ri=200 olduğu durumda meydana geldiği belirlenmiştir. Ayrıca; çalışmada Nu sayısı için bir korelasyon elde edilmiştir. Sayısal çalışmanın sonuçları literatürde bulunan deneysel çalışmalarla da karşılaştırılarak; sıcaklık dağılımını ve akış özelliklerini iyi şekilde temsil edebildiği görülmüştür.

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi

Field :   Mimarlık, Planlama ve Tasarım; Mühendislik

Journal Type :   Uluslararası

Metrics
Article : 2.369
Cite : 6.286
Gazi Üniversitesi Mühendislik Mimarlık Fakültesi Dergisi