User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 9
Diagnosis of cholesteatoma by the b1000 value DWI MRI according to the signal intensity
2020
Journal:  
Medical Science and Discovery
Author:  
Abstract:

Objective: The cholesteatoma (CL) can be evaluated visually or numerically on an apparent diffusion coefficient (ADC) map, which obtained from at least two different b-valued diffusion-weighted imaging (DWI). In this study, we aimed to evaluate the signal intensity (SI) of the lesion both visually and numerically only on the DWI image without ADC. In case of positive results a second  ‘b’ value is not required, so this method could be shorten the duration of the MRI examination. Material and Methods: Between January 2017 and May 2018, we included patients with chronic otitis media (COM) with a clinical suspicion of primary CL who underwent DWI. Two radiologists and one ear, nose, throat specialist evaluated the radiological images and the pathology results. Results: The mean SI measurement was significantly higher in the CL group by both observers (observer LR; CL: 107.94 ± 53.36, COM: 37.34 ± 14.70, observer FC; CL: 108.56 ± 50.00, COM: 37.06 ± 15.44; p<0001). ROC analysis showed that a mean SI value of 48.6 was the cut-off value in predicting the diagnosis of CL. The mean SI was significantly higher in the CL group (p<0.001). Conclusion: We demonstrated a significant difference between CL and COM concerning the diagnosis by visual and numerical signal evaluation only via b1000 valuable images. In false-positive cases, ADC is still confirmatory for high diagnostic accuracy.    

Keywords:

null
2020
Author:  
0
2020
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Medical Science and Discovery

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 743
Cite : 77
Medical Science and Discovery