User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 8
Investigation of optimum external wall insulation thickness of a house two different climate regions
2022
Journal:  
International Journal of Energy Studies
Author:  
Abstract:

In this study, a residential single-family house with an area of 100 m2 was modeled utilizing the Design Builder program in order to calculate the optimum insulation thickness of the external wall including 20% window-to-wall ratio (WWR) for two different climate zones Kirkuk, Iraq city as drying hot which showed heating degree day (HDD) and cooling degree day (CDD) rate between (730) and (1700) degrees. Between (2507) and (178) degrees of the year, the heating degree day (HDD) and cooling degree day (CDD) rate were indicated espectively for the Konya, Turkey city as cold climate zone. The results obtained in the cost analysis of the (XPS , EPS, rock wool and glass wool) insulation materials, furthermore, electric was chosen for Kirkuk hot seasons as a energy source as well as selecting natural gas as energy source for Konya cooling seasons and commercially available materials of the two countries were taken into account. The results showed that, the best exterior wall insulation thickness was determined to be Xopt = 7 cm and Xopt = 19 cm, respectively. At Xopt = 9 cm, the greatest rate of XPS for Kirkuk city was roughly 6.7 percent. Xopt = 7 cm and Xopt = 15 cm findings were achieved as a result of the insulation applied to the building components for Konya. Following that, the energy savings were calculated, and an XPS of 8.3 percent was obtained at Xopt = 11 cm. As a consequence, XPS material was determined to be appropriate for two climatic zones. To sum up, XPS material was determined to be ideal for Kirkuk, which has a hot climate, and Konya, which has a cool environment.

Keywords:

null
2022
Author:  
0
2022
Author:  
Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








International Journal of Energy Studies

Journal Type :   Uluslararası

International Journal of Energy Studies