User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 15
 Downloands 3
Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading
2010
Journal:  
Frontiers in Dentistry
Author:  
Abstract:

Objective: Vertical bone loss evaluations in the Nobel Biocare Replace® Select Tapered TM implant system in the human after one-year loading time. Materials and Methods: This retrospective cross-sectional study was performed on 31 patients (14 men, 17 women; mean age, 60.39 years) receiving 170 implants (mean, 5.48 for each patient) of Groovy and Non-groovy designs in the Nobel Biocare Replace® Select Tapered TM system. The marginal bone loss was measured at mesial and distal aspects of the implants on OPG x-rays after one-year follow-up. The data regarding the patient's gender, age, history of disease, smoking, bone type at implant location, loading time of prosthesis and implant, implant design, diameter and length were recorded by the patients' records and interview. The data were subjected to multiple linear regression and Pearson coefficient ratio regarding different factors. Results: The mean (standard deviation) distal, mesial and overall bone loss was 0.688 mm (0.851), 0.665 mm (0.849) and 0.935 mm (0.905), respectively in the studied implants. No significant differences were found regarding implant location, bone quality at the implant region, implant design and bone graft reception. In addition, no significant correlation was found between the occurred bone loss and implant diameter, length and number of used splints. Conclusion: Due to the criteria mentioned for implant success in term of bone loss values after one-year loading time, Noble Biocare Replace® Select Tapered TM implant system is an acceptable treatment option for implant restorations in this regard.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Frontiers in Dentistry

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 854
Cite : 372
Frontiers in Dentistry