User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 13
 Downloands 1
Determination of Normal Values of Optic Nerve Sheath Diameter in Turkish Adult Population Using Magnetic Resonance Imaging
2021
Journal:  
Journal of Experimental and Clinical Medicine
Author:  
Abstract:

Abstract Title: Determination of Normal Values of Optic Nerve Sheath Diameter in Turkish Adult Population Using Magnetic Resonance Imaging Introduction: The measurement of optic nerve sheath diameter (ONSD) is a reliable tool for the estimation of increased intracranial pressure (ICP). However, it is known that racial changes can occur in human anatomy. In the present study we aimed to determine the normal values of ONSD in Turkish adult population. Methods: This retrospective study involved the collection of data between June 1, 2015 and May 31, 2019, and was conducted on 291 adults known to have no increased cranial/intraocular pressure. The ONSD was measured at 3 mm posterior to the globe on MR images. Results: 291 subjects were enrolled, 63.6% of whom were female. The total median ONSD was 4.40mm (4.20 - 4.70). The median ONSD of the male participants was 4.50mm (4.25-4.75), of the female participants was 4.35mm (4.15-4.50) and the difference was statistically significant (p = 0.001). According to statistical analysis, it was found that only the presence of chronic renal failure altered the median of ONSD among the comorbid diseases (p = 0.042). Conclusions: Monitoring and treating increased ICP is crucial. Thanks to an ONSD with a known normal value, recognition and emergency management of this pathology would be easier. We think our study is noteworthy because it is the first study investigating the normal ONSD value in Turkish adult population. Keywords: Optic nerve sheath diameter; Normal value; MRI; Turkish adult population.

Keywords:

2021
Author:  
0
2021
Author:  
Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Journal of Experimental and Clinical Medicine

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 1.457
Cite : 910
2023 Impact : 0.034
Journal of Experimental and Clinical Medicine