User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 12
 Downloands 2
Improvement method for calculation gate circuit insulation monitoring 3B with measuring relay consisting of two coils
2014
Journal:  
Technology Audit and Production Reserves
Author:  
Abstract:

Efficiency of electrical breaker is identified with the level reached in their risk of electric shock, and this level is determined by the following parameters. The first - a line of protective characteristics circuit breakers electrical safety requirements, the second - the ability to retain this correspondence for all occurring negative impacts of factors of production, and the third - the ability to provide a functional interaction, members of the circuit breakers leakage relay and power switching device network. The second and third parameters are determined on the basis of compliance with the requirements of the circuit breakers imposed operating conditions of mining production. The paper presents an improved method of calculating the gate control circuit with two-winding insulation 3B measuring relays. In the research proposed a new method of calculation and the optimization of circuit parameters the automatic control of isolation  ACI-380 in order to increase its sensitivity from 0.33 to 0.63 mA/com in the same functional characteristics.The results of the research will enhance the reliability of the relay leakage, thereby improving the protection of persons against electric shock in LV networks with isolated neutral and will reduce the likelihood of ignition of fire-damp and coal dust leakage current.  Author Biographies Александр Александрович Харитонов, SHEI "National University of Krivoy Rog", XXII Party Congress 11, Krivoy Rog, Ukraine, 50027

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Technology Audit and Production Reserves

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 2.454
Cite : 269
2023 Impact : 0.047
Technology Audit and Production Reserves