User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 23
 Downloands 2
A NOVEL FRAMEWORK FOR CARDIAC ARRHYTHMIA CLASSIFICATION BASED ON SUBSPACE PROJECTION AND DECISION TREE
2020
Journal:  
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering
Author:  
Abstract:

Cardiac arrhythmia basically refers to abnormal activity of heart. Correct classification of cardiac arrhythmia is therefore crucial for appropriate treatment of heart diseases. In this paper, a novel approach is proposed for cardiac arrhythmia classification. Initially, the feature vectors extracted from raw electrocardiogram (ECG) signals are projected into a particular subspace obtained via the Common Vector Approach, which is an effective subspace method. The projected vectors are then fed into two distinct decision-tree-based classifiers—namely, C4.5 and random forest. The results obtained from the proposed approach are compared with those obtained with the original feature vectors using the same classifiers. For this purpose, the well-known MIT-BIH arrhythmia database was utilized. Six different sets of features based on QRS, time-domain, wavelet transform and power spectral density are derived from ECG signals in this database. The feature sets are then used in the classification of five main beat types including non-ectopic, ventricular ectopic, supraventricular ectopic, fusion and unknown. The experimental results reveal that the recognition performances achieved by most of the projected features are explicitly higher than those obtained with the original ones. In addition, the classification accuracy of the proposed approach climbs to 100% for the test set.

Keywords:

0
2020
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering

Field :   Fen Bilimleri ve Matematik; Mühendislik; Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 648
Cite : 330
Eskişehir Technical University Journal of Science and Technology A - Applied Sciences and Engineering