User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 4
BİR İNFLUENZA VİRÜSÜ NÖRAMİNİDAZ İNHİBİTÖRÜ OLAN PERAMIVİR’İN SAPTANMASI İÇİN MOLEKÜLER BASKI POLİMER İLE ELEKTROKİMYASAL SENSÖRÜN GELİŞTİRİLMESİ
2024
Journal:  
Ankara Üniversitesi Eczacılık Fakültesi Dergisi
Author:  
Abstract:

Amaç: Grip virüsleri, gribin en yaygın nedenidir. Antiviral ilaçlar virüsün enfekte hücreler yoluyla yayılmasını engeller. Peramivir, influenza virüsü nöraminidazının inhibitörü olan antiviral ilaçlardan biridir. Çalışmamızda Peramivir tayini için MIP tabanlı bir elektrokimyasal sensör geliştirilmesi amaçlanmıştır. Bu çalışma, Peramivir analizi için geliştirilen ilk elektrokimyasal sensör çalışmasıdır. MIP(PERA)/GCE, Peramivir varlığında 4-aminofenol (4-AP) ve ortofenilendiaminin (o-PD) monomerlerin elektropolimerizasyonu ile geliştirilmiştir. Geliştirilen MIP(PERA)/GCE, Peramivir analizi için ticari serum örneğine uygulanmıştır. Gereç ve Yöntem: Peramivir, Tobio Novelpharma ilaç şirketi (İstanbul, Türkiye) tarafından sağlanmıştır. Potasyum ferrisiyanür ([K3Fe(CN)6]), potasyum ferrosiyanür (K4[Fe(CN)6].3H2O) potasyum klorür(KCl), 4-aminofenol (4-AP) ve ortofenilendiamin (o-PD), sentetik insan serumu, dopamin, askorbik asit, ürik asit, parasetamol, KNO3, Na2SO4 ve MgCl2 Sigma-Aldrich'ten (St. Louis, Missouri, ABD) temin edilmiştir. Metanol, asetik asit, okzalik asit, hidroklorik asit, asetonitril sodyum hidroksit ve etanol Merck tarafından tedarik edilmiştir. Redoks işlemi, Dropsens μStat 400 Bipotantiostat/ Galvanostat (Metrohm, Herisau, İsviçre) tarafından döngüsel voltametri (CV) ve diferansiyel puls voltammetrisi (DPV) kullanılarak gerçekleşmiştir. Üç elektrotlu sistemler, bir camsı karbon çalışma elektrodu (GCE, 3mm2, BASi, ABD), doymuş bir Ag/AgCl referans elektrodu ve bir Pt telinden oluşmuştur. Sonuç ve Tartışma: Geliştirilen sensör, 0,158 pM en düşük tayin limiti ile 1-10 pM doğrusal bir aralık göstermiştir. Geliştirilen MIP sensörü ticari bir serum örneğine uygulanmıştır. MIP(PERA)/GCE sensörü ile %101.81'lik yüksek bir geri kazanımla ticari serum örneklerinden peramivir saptanmıştır.

Keywords:

Development Of Electrochemical Sensor By Molecularly Imprinting Polymer For Detection Of An Influenza Virus Neuraminidase Inhibitor Peramivir
2024
Author:  
Abstract:

Objective: Influenza viruses are the most common cause of influenza. Antiviral drugs prevent the spread of the virus through the infected cells. Peramivir is one of the antiviral drugs that is an inhibitor of influenza virus neuraminidase. In our study, we aimed to develop a MIP-based electrochemical sensor to determine Peramivir. This study is the first to create an electrochemical sensor for Peramivir. MIP(PERA)/GCE was fabricated with the electropolymerization of 4-aminophenol (4-AP) and ortophenilendiamine (o-PD) in the presence of Peramivir. The developed MIP(PERA)/GCE was applied to the commercial serum sample for analysis of Peramivir. Material and Method: PERA is supplied by Tobio Novelpharma pharmaceutical company (İstanbul, Türkiye). Potassium ferricyanide ([K3Fe(CN)6]), potassium ferrocyanide (K4[Fe(CN)6].3H2O), and potassium chloride (KCl), 4-aminophenol (4-AP) and ortophenilendiamine (o-PD), commercial human serum sample, dopamine, ascorbic acid, uric acid, paracetamol, KNO3, Na2SO4 ve MgCl2 were obtained from Sigma-Aldrich (St. Louis, Missouri, USA). Methanol, acetic acid, oxalic acid, hydrochloric acid, acetonitrile, sodium hydroxide, and ethanol were purchased by Merck. The redox process was investigated using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) by the Dropsens μStat 400 Bipotantiostat/ Galvanostat (Metrohm, Herisau, Switzerland). Three-electrode systems consisted of a glassy carbon working electrode (GCE, 3mm2, BASi, USA), a saturated Ag/AgCl reference electrode, and a Pt wire. Result and Discussion: The sensor exhibits a linear range of 1-10 pM with a detection limit of 0.158 pM. The MIP(PERA)/GCE sensor could detect PERA from commercial serum samples with a high recovery of 101.81%.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Ankara Üniversitesi Eczacılık Fakültesi Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 863
Cite : 481
2023 Impact : 0.032
Ankara Üniversitesi Eczacılık Fakültesi Dergisi