User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
  Citation Number 3
 Views 36
 Downloands 1
GWP Değeri Düşük Soğutucu Akışkanların Kullanıldığı Kaskad Soğutma Sisteminin Karşılaştırmalı Performans Analizi
2020
Journal:  
El-Cezeri Journal of Science and Engineering
Author:  
Abstract:

Bazı endüstriyel soğutma uygulamaları için düşük sıcaklıklara ihtiyaç duyulur. Tek kademeli soğutma sistemleri ile bu sıcaklığı elde etmek oldukça zor ve ekonomik açıdan avantajlı değildir. Bu nedenle daha düşük sıcaklıkta soğutma uygulamalarında kaskad soğutma sistemleri tercih edilir.   Bu çalışmada, yeni nesil soğutucu akışkan çiftlerinin kullanıldığı kaskad soğutma sisteminin performans analizi yapılmıştır. Kaskad sisteminde ozon delme potansiyeli (ODP) sıfır olan ve küresel ısınma potansiyeli (GWP) değeri düşük R454C/ R1234ze, R454C/ R1234yf, R454C/R717, R744/R290 ve R744/R717 soğutucu akışkan çiftleri kullanılmıştır. Yapılan analizler sonucunda en yüksek COP değerlerine R454C/R717 akışkan çifti kullanıldığında ulaşılmıştır.

Keywords:

Comparative performance analysis of the cascade cooling system in which low cooling fluids are used
2020
Author:  
Abstract:

Low temperatures are required for some industrial cooling applications. With one-step cooling systems, getting this temperature is quite difficult and is not economically advantageous. Therefore, cascade cooling systems are preferred in lower temperature cooling applications.   In this study, the performance analysis of the cascade cooling system in which the new generation of cooling fluid pairs are used was made. The cascade system has zero ozon dive potential (ODP) and low global warming potential (GWP) values R454C/R1234ze, R454C/R1234yf, R454C/R717, R744/R290 and R744/R717 cooling fluid pairs. The highest COP values were achieved when the fluid pair R454C/R717 was used.

Keywords:

Comparative Performance Analysis Of Cascade Refrigeration System Using Low Gwp Refrigerants
2020
Author:  
Abstract:

Some industrial cooling applications require low temperatures. With single stage refrigeration systems, it is difficult to obtain this temperature and is not economically advantageous. Therefore, cascade refrigeration systems are preferred for lower temperature cooling applications. In this study, the performance analysis of the cascade refrigeration system using the new generation of refrigerant pairs was performed. In the cascade system, GWP R454C/ R1234ze, R454C/ R1234yf, R454C/R717, R744/R290 ve R744/R717 refrigerant pairs were used. As a result of analyzes, the highest COP values were reached when the R454C/R717 fluid pair was used. 

Keywords:

Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles






El-Cezeri Journal of Science and Engineering

Journal Type :   Ulusal

Metrics
Article : 718
Cite : 1.652
2023 Impact : 0.127
El-Cezeri Journal of Science and Engineering