User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
Carbon Paste Electrode Modified by Dibenzo 18-crown-6 for the Determination of Pb in Carrot Using Differential Pulse Voltammetry
2023
Journal:  
Journal of the Turkish Chemical Society Section A: Chemistry
Author:  
Abstract:

In this research, the modification of carbon paste electrode (CPE) using dibenzo 18-crown-6 was carried out to detect Pb level in carrot. The purpose of this electrode modification is to increase the sensitivity of the measurement. The optimized parameters were scan rate, composition of dibenzo 18-crown-6 in carbon paste, and supporting electrolyte. Measurements were validated by determining the linear concentration range, detection limit (LoD), quantification limit (LoQ), repeatability, selectivity, and recovery. At the best measurement conditions, the modified CPE (CPE-Dbc) was applied to determine Pb in carrot. The optimum measurements conditions were obtained the optimum concentration of crown ether in carbon paste was 0.8%, the scan rate using CPE at 15 mV/s, increased to 20 mV/s, and H2SO4 solution as supporting electrolyte. The linear concentration was found in the range of 5-100 µg/L using CPE and became wider to 5-2000 µg/L using CPE-Dbc. The values of LoD and LoQ measurement using CPE were 0,3575 µg/L and 0,3583 µg/L, and decreased to 0,1265 µg/L and 0,1266 µg/L using CPE-Dbc. CPE and CPE-Dbc had good precision with Horwitz ratio values were 0,2231 and 0,2183, which is smaller than two. The percentage of recovery of Pb in the mixture of standard and sample solutions was (88,97 ± 2,76)%. The presence of Cu, Cd and Na in the solution did not interfere the measurement of Pb. The concentration of Pb in carrot sample was (1,8423 ± 0,0002) mg/kg, which was higher than the acceptable concentration according to SNI No. 7387:2009, which is 0,5 mg/kg.

Keywords:

0
2023
Author:  
Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Journal of the Turkish Chemical Society Section A: Chemistry

Field :   Fen Bilimleri ve Matematik

Journal Type :   Ulusal

Metrics
Article : 843
Cite : 319
2023 Impact : 0.03
Journal of the Turkish Chemical Society Section A: Chemistry