User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 7
 Downloands 3
Promax Artefakt Azaltma Algoritmasının Titanyum ve Zirkonyum İmplantların Oluşturduğu Artefaktlar Üzerine Etkisi
2020
Journal:  
7tepe Klinik
Author:  
Abstract:

GİRİŞ ve AMAÇ: Artefaktlar görüntü kalitesini düşürürler. Literatürde titanyum (Ti) ve zirkonyum (Zr) implant artefaktları ile ilgili çalışma sayısı kısıtlıdır. Bu çalışmanın amacı, farklı çekim parametreleri ile ProMax Artefakt Azaltma Algoritması’nın (AAA) konik ışınlı bilgisayarlı tomografi (KIBT) görüntülerinde Ti ve Zr implantların oluşturduğu artefaktlar üzerine olan etkisinin değerlendirilmesi ve karşılaştırılmasıdır. YÖNTEM ve GEREÇLER: Bir Zr ve bir Ti implant sığır kaburgasına yerleştirildi. Bu kemik ProMax 3D Mid KIBT cihazı ile tarandı. Görüntüler 70, 76, 80, 86 ve 90 kVp’de, 2 farklı voksel boyutunda (0.2 ve 0.4 mm) elde edildi. AAA kullanılarak ve kullanılmadan 20 çekim yapıldı. Elde edilen görüntüler ImageJ programına aktarıldı. Ortalama gri değeri (GV) ve standart sapma (SD) ile kontrast-gürültü oranı (CNR) hesaplandı. İstatistiksel analizlerde Pearson’s korelasyon katsayısı, Student’s t-test, ANOVA and multipl regresyon analizi testleri kullanıldı. BULGULAR: AAA her iki implant grubunda da SD’yi anlamlı derecede azalttı (p<0.001) ve bu azalma Zr implant için daha yüksekti. Algoritmanın aktivasyonu ile kVp ve Zr implanttaki SD arasında önemli bir negatif korelasyon gözlendi (p<0.05). Her iki implant grubunda da GV ve CNR değerleri anlamlı olarak yükseldi ve bu artış Zr grubunda daha yüksekti (p<0.001). TARTIŞMA ve SONUÇ: Zr, KIBT görüntülerini Ti’den daha fazla bozmaktadır. Promax cihazının AAA her iki implant grubunda da görüntü kalitesini iyileştirmektedir ve Zr implantlar üzerine etkisi daha yüksektir.

Keywords:

The Effect of Promax Artefact Reduction Algorithm on the Artefact Created by Titanium and Zirconium Implants
2020
Journal:  
7tepe Klinik
Author:  
Abstract:

Introduction and Purpose: Artifacts decrease image quality. In literature, the number of work related to the implant artefacts of titanium (Ti) and zirconium (Zr) is limited. The aim of this study is to evaluate and compare the effects of the ProMax Artefact Reduction Algorithm (AAA) on the artefacts created by Ti and Zr implants in the conic-ray computer tomography (KIBT) images with different drawing parameters. Method and Requirements: A Zr and a Ti implant were placed in the cattle cage. This bone was scanned with the ProMax 3D Mid KIBT device. The images were obtained in 70, 76, 80, 86 and 90 kVp, in 2 different voksel sizes (0.2 and 0.4 mm). AAA was made with and without use 20 screens. The images were transferred to the ImageJ program. The average grey value (GV) and the standard deviation (SD) are calculated with the contrast-bullying ratio (CNR). Statistical analysis used Pearson's correlation ratio, Student's t-test, ANOVA and multiple regression analysis tests. AAA has significantly reduced SD in both implant groups (p<0.001) and this reduction was higher for the Zr implant. A significant negative correlation between the algorithm activation and the SD in the kVp and Zr implant was observed (p<0.05). The GV and CNR values increased significantly in both the implant groups, and this increase was higher in the Zr group (p<0.001). CONTRIBUTION and RESULT: Zr disrupts KIBT images more than Ti. The AAA of the Promax device also improves the image quality in both implants and the effect on Zr implants is higher.

Keywords:

0
2020
Journal:  
7tepe Klinik
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








7tepe Klinik

Field :   Sağlık Bilimleri

Journal Type :   Ulusal

Metrics
Article : 364
Cite : 87
2023 Impact : 0.014
7tepe Klinik