User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 16
 Downloands 3
Safety and Clinical Performance of Biodegradable Polymer-Coated Ultra-Thin Everolimus-Eluting Stents in “Real-World” Patients: A Multicenter Registry (PERFORM-EVER)
2022
Journal:  
The Anatolian Journal of Cardiology
Author:  
Abstract:

Background: Tetrilimus (Sahajanand Medical Technologies Limited, Surat, India) is a biodegradable polymer-coated everolimus-eluting stent with cobalt–chromium stent platform and ultra-thin (60 µm) strut thickness. We aimed to report 1-year safety and clinical performance of Tetrilimus everolimus-eluting stent in patients with coronary artery disease in “real-world” clinical practice. Methods: The PERFORMance of biodegradable polymer-coated ultra-thin EVERolimuseluting stents was an observational, multicenter, single-arm, and investigator-initiated retrospective registry. All “real-world” patients who had received Tetrilimus everolimuseluting stent between July-2015 and October-2016 at four study centers were analyzed. The data were collected retrospectively either by extraction from existing databases in consecutive fashion where index and follow-up data existed or the follow-up was obtained by telephonic contact. Primary endpoint was 1-year incidence of target lesion failure, which was defined as a composite endpoint of cardiac death, myocardial infarction, and target lesion revascularization by percutaneous or surgical methods. The Academic Research Consortium-defined stent thrombosis was assessed as additional safety endpoint. Results: During the study period, 815 Tetrilimus everolimus-eluting stents (1.4 ± 0.5 stent/ patient) were implanted to treat 735 coronary lesions (1.1 ± 0.3 stent/lesion) in 594 patients (mean age: 55.6 ± 12.1 years). The cumulative incidence of target lesion failure at 1-year follow-up was 3.7%, which included 9 (1.5%) cardiac deaths, 8 (1.4%) myocardial infarctions, and 5 (0.8%) target lesion revascularizations. There were 5 (0.8%) cases of probable stent thrombosis and 4 (0.7%) cases of possible stent thrombosis at 1-year follow-up. Conclusion: Low incidences of target lesion failure and stent thrombosis at 1-year followup indicates that biodegradable polymer-coated ultra-thin Tetrilimus everolimus-eluting stents may have encouraging safety and efficacy in unselected real-world patients with coronary artery disease, including those with high-risk characteristics and complex lesions.

Keywords:

0
2022
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles












The Anatolian Journal of Cardiology

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 507
Cite : 218
2023 Impact : 0.101
The Anatolian Journal of Cardiology