User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 38
 Downloands 3
Femur başı epifizinin stabil tip hafif ve orta dereceli kaymasında tek vida ile olduğu pozisyonda tespit
2015
Journal:  
Şişli Etfal Hastanesi Tıp Bülteni
Author:  
Abstract:

Amaç: Femur başı epifiz kayması (FBEK) adölesan çağın sık görülen kalça rahatsızlıklarındandır. Tanı genellikle gecikmektedir. Çalışmanın amacı; hafif ve orta şiddetli stabil tip femur başı epifiz kaymasının tek vida ile olduğu pozisyonda tespitinin sonuçlarını değerlendirmektir. Gereç ve Yöntem: 2000-2012 yılları arasında FBEK olan 10 hastanın, 12 kalçası tek vida ile olduğu pozisyonda tespit edildi. Tanı konduğu zaman immobilizasyon ve erken cerrahi tedavi uygulandı. Tanı anında vücut kitle indeksi (VKİ), eklem hareket açıklığı, kalça yan radyografisinde kayma açısı (karşı kalçanın normal açısı çıkarılmadan) ve ameliyat sonrası dönemde Heyman ve Herndon’ un klinik, Boyer’in radyolojik sonuçları değerlendirildi. Bulgular: Hastaların yaş aralığı 11.4±1.5 (9-14) yıl ve ortalama takip süresi 62 (14-119) aydı. Southwick metoduna göre ortalama kayma açısı 40° (26-50), ortalama VKİ 27 kg/m2 (>95 persentil) idi. Ameliyat öncesi ortalama kalça fleksiyon, iç ve dış rotasyon dereceleri sırasıyla 100° (50°-120°), 12° (0°-30°), 64° (20°-90°) ve ameliyat sonrası değerleri ise sırasıyla 119° (100°-130°), 30° (10°-60°), 62° (50°-80°) olarak saptandı. Fleksiyon ve iç rotasyon hareket açıklık değişimleri istatistiksel olarak anlamlı idi (p<0.05). Heyman ve Herndon’un klinik ve Boyer’in radyolojik sonuçları başarılıydı. Sonuç: Stabil olgularda redüksiyon uygulanmadan yapılan tek vida ile tespitin başarılı bir yöntem olduğu görülmektedir. Karşı kalça için koruyucu tespit yerine yakın takip önermekteyiz.

Keywords:

Femur head epiphysis is detected in a position that is stable type of light and medium switches with a single wire.
2015
Author:  
Abstract:

Goal: Femur headache epifysal swelling (FBEK) is one of the common neck disorders of the age. The diagnosis is usually delayed. The purpose of the study is to evaluate the results of the detection in the position where the light and medium-intensity stable type of femur head epiphysis is swallowed with a single wire. Method and means: 10 patients with FBEK between 2000 and 2012 were identified in a position where 12 shoulders were with a single wire. When diagnosed, immobilization and early surgical treatment were applied. The immediate diagnosis of the body mass index (BMI), joint movement clarity, the swing angle in the back side radiography (without the normal angle of the opposite back) and the clinic of Heyman and Herndon in the postoperative period, the radiological results of Boyer were evaluated. The age range of patients is 11.4±1. 5 (9-14) years and the average tracking time was 62 (14-119) months. According to the Southwick method, the average sliding angle was 40° (26-50), and the average VKI was 27 kg/m2 (>95 per cent). The average pre-operative column flessions, internal and external rotation degrees were set at 100° (50°-120°), 12° (0°-30°), 64° (20°-90°) and postoperative values at 119° (100°-130°), 30° (10°-60°), 62° (50°-80°) respectively. Flexion and internal rotation movement open changes were statistically meaningful (p<0.05). Heyman and Herndon's clinical and Boyer's radiological results were successful. The result: in stable cases, it is seen as a successful method of detection with a single wire made without the application of reduction. We recommend close tracking instead of protective detection for the opposite back.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Şişli Etfal Hastanesi Tıp Bülteni

Field :   Sağlık Bilimleri

Journal Type :   Ulusal

Metrics
Article : 901
Cite : 1.228
2023 Impact : 0.019
Şişli Etfal Hastanesi Tıp Bülteni