User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 19
 Downloands 2
Shear wave versus strain elastography in the differentiation of benign and malignant breast lesions
2019
Journal:  
Turkish Journal of Medical Sciences
Author:  
Abstract:

Background/aim: To evaluate and compare the diagnostic performances of shear wave elastography (SWE) and strain elastography (SE) in the differentiation of benign and malignant breast lesions.Materials and methods: The current study included 87 breast lesions in 84 patients. The Breast Imaging Reporting and Data System (BIRADS) categories were determined with ultrasound features. The maximum shear wave velocity (SWV), mean SWV, maximum SWV to fat SWV ratio, and mean SWV to fat SWV ratio were measured using SWE. The strain ratio (SR) was calculated as the ratio of lesion strain to the adjacent fat strain using SE. Receiver operating characteristic (ROC) curves were constructed to assess and compare the diagnostic performances of each parameter. Results: Forty-five benign and 42 malignant lesions were diagnosed. The sensitivity and specificity of the BIRADS classification was 100% and 35.6%, respectively. Selecting a cutoff SR value of 3.22 led to an 88.1% sensitivity and an 88.4% specificity (AUC: 0.913 [95% CI: 0.854?0.971], P < 0.001). Selecting cutoff maximum SWV value of 3.41 m/s led to an 88.1% sensitivity and an 86.7% specificity (AUC: 0.918 [95% CI: 0.858?0.978], P< 0.001). The diagnostic performance of the maximum SWV, mean SWV, and maximum SWV to fat SWV ratio were similar to the diagnostic performance of the SR (P = 1.00, P= 1.00, P= 0.629, respectively). Conclusion: SE and SWE are both feasible imaging modalities in the differentiation of malignant and benign breast lesions with similar diagnostic performances.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Turkish Journal of Medical Sciences

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 4.115
Cite : 3.307
2023 Impact : 0.011
Turkish Journal of Medical Sciences