User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 4
 Downloands 2
Grafen Oksit/Poliimid Temelli Biyosensör Kullanarak Melatonin ve Dopaminin Voltametrik Analizi
2020
Journal:  
İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi
Author:  
Abstract:

Bu araştırmada, melatonin (MET) ve dopaminin (DP) eş zamanlı analizi için, Pt elektrodun modifikasyonu ile grafen oksit/poliimit (GO/PI) kompozit elektrot hazırlanmıştır. İlk olarak, GO/PI kompozit yapısı, 2,6-diaminopiridin temelli PI ve % 5 GO'den sentezlenmiştir. Daha sonra membran olarak elde edilen kompozit yapı elektrot yüzeyi üzerine kaplanmıştır. Hazırlanan GO/PI kompozit elektrodunun MET ve DP yanıtları Diferansiyel Puls Voltametri (DPV) tekniği ile araştırılmıştır. MET ölçümleri için doğrusallık 85- 105 µM (R2=0.9976) konsantrasyon aralığında elde edilmiştir. DP analizi için de doğrusallık 85-105 µM konsantrasyon aralığında izlenmiştir (R2=0.9988). GO/PI ile modifiye edilmiş elektrodun tayin limitleri, MET ve DP için sırasıyla yaklaşık 13.45x10−5 M ve 9.61x10−5 M’dı. Hazırlanan GO/PI kompozit modifiye elektrot, MET ve DP için iyi tekrarlanabilirlik, geniş doğrusal aralık ve hassasiyet sergilemiştir. Elde edilen sonuçlar, GO/PI kompozitinin ortamda ürik asit (UA) varlığında, MET ve DP’i eş zamanlı olarak analiz etmek için mükemmel bir membran olarak kullanılabileceğini göstermiştir.

Keywords:

Voltammetric Analysis Of Melatonin and Dopamine By Using Graphene Oxide/polyimide Based Biosensor
2020
Author:  
Abstract:

In this research, for the simultaneous analysis of melatonin (MET) and dopamine (DP), graphene oxide/polyimide (GO/PI) composite electrode was prepared with the modification of Pt electrode. Firstly, GO/PI composite structure was synthesized from 2,6-diaminopyridine based polyimide and 5% GO. Then, the obtained composite structure as the membrane was coated on the electrode surface. MET and DP responses of the prepared GO/PI composite electrode were investigated by Differential Pulse Voltammetry (DPV) technique. Linearity was obtained over a concentration range of 85-105 µM for MET (R2 = 0.9976). For DP analysis, the linearity was also monitored over a concentration range of 85-105 µM (R2=0.9988). The detection limits of GO/PI modified electrode were approximately 13.45×10−5 M and 9.61×10−5 M for MET and DP, respectively. The prepared GO/PI composite modified electrode exhibited good repeatability, wide linear range and sensitivity for MET and DP. The obtained results indicated that while uric acid (UA) is present in the medium, GO/PI composite can be used as an excellent membrane in the design of voltammetric sensors to analyze MET and DP simultaneously.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles






İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 420
Cite : 979
2023 Impact : 0.165
İnönü Üniversitesi Sağlık Hizmetleri Meslek Yüksek Okulu Dergisi