Devising a method for predicting a blood pressure level based on electrocardiogram and photoplethysmogram signals
2022
Journal:  
Eastern-European Journal of Enterprise Technologies
Author:  
Abstract:

Determining the level of blood pressure (BP) in a non-invasive way and without a sphygmomanometer cuff is of great relevance when conducting continuous monitoring or screening studies. In this regard, a method for predicting BP parameters based on the signals of the photoplethysmogram (PPG) and electrocardiogram (ECG) signals has been developed. It is proposed to use, as informative features, the time of pulse wave propagation (PTT) and a set of calculated pulse parameters of PPG. PTT is defined as the time intervals between the R-wave of the ECG and the corresponding characteristic points on the PPG acquired optically from the finger. As parameters of the PPG pulse, the known characteristics of this signal described in the literature are used, as well as additional informative features selected during the study. In accordance with the above, the tools of machine learning theory were used to construct a classifier model and regression models. The approach described in this paper to determine BP makes it possible to use 10-second ECG signals in any of the 12 common leads and PPG signals from any optical type of sensor. The built model of the classifier detects three levels of BP: low, normal, and high, at the accuracy metric=0.8494. The regression models predict systolic, diastolic, and mean BP parameters in accordance with the requirements of the British Hypertension Society (BHS) standard by the magnitude of the absolute error. The proposed method for assessing the level of BP involves real-time measurements and can be used in the design of measuring equipment for screening studies, as well as in continuous monitoring tasks within the framework of BHS requirements. Author Biographies Alexey Savostin, Manash Kozybayev North Kazakhstan University Candidate of Technical Sciences, Professor Department of Energetic and Radioelectronics

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Eastern-European Journal of Enterprise Technologies

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 4.764
Cite : 4.485
2023 Impact : 0.294
Eastern-European Journal of Enterprise Technologies