User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 20
 Downloands 2
Determination of sertindole in biological material by gas chromatography-mass spectrometry
2017
Journal:  
ScienceRise: Pharmaceutical Science
Author:  
Abstract:

The treatment by the new generation antipsychotic remedy Sertindole is often accompanied by QT interval prolongation accompanied and neuroleptic malignant syndrome, which often leads to fatal consequences, in case of its overdose or mixing with some other drugs. In most cases, the anatomical pathology analysis results do not give any sudden death explanation. Aim. Identification and quantitative determination of Sertindole using Gas Chromatography - Mass spectroscopy method in samples obtained after purification of the extracts from the biological material (liver) by solid-phase extraction. Methods. Sertindole was isolated from the biological material by the mixture of Acetonitrile - Perchloric acid 70% (1:1) with the following liquid extraction by 1,2-Dichloroethane (рН 11). The extracts after purification using the SPE Oasis HLB 30 mg (Waters, USA) cartridges were eluted by Ethanol 96%, evaporated to dryness under Nitrogen flow, and then the residues were dissolved in 250 μl of Methanol. Identification and assay of Sertindole in the solutions and the model samples were carried out using Agilent 6890N chromatograph equipped by 5978B Mass detector (Agilent Technology, USA), RTX-5 column was used, 30m×0,25mm, 0,25 μm (Restek, USA). Temperature gradient: 50 °С (0,5 min), 25 °С/min till 150 °С, and then the temperature rise was 10 °С/min until 320 °С was reached. Isothermal mode was set at 320 °С (30 min). Injector temperature was 270 °С. Helium was used as a carrier gas (3 ml/min). Mass detection was performed at 70 еV electronic ionization and 400V voltage. Results. At the offered conditions of the analysis Sertindole retention time was 27.79±0.05 min (RSD 0,17 %). The method is characterized by linearity within 50–200 μg/ml. It was found that Sertindole detection limit without prior derivatization in SCAN mode is 25 μg/ml. In the model samples of liver tissues Sertindole was identified and quantitatively determined. The drug detection limit in the biological material is 2 μg/g.Conclusion. Chromatographic conditions with Mass-selective detector (GC/MS) for Sertindole analysis were developed for the first time. The basic patterns of primary Sertindole fragmentation were shown. The scheme of chemical and toxicological analysis of the biological material to determine Sertindole by GC/MS method was offered. The developed method for Sertindole determination can be used in departments of forensic toxicology bureau Author Biographies Sophia Davydovych, Danylo Halytsky Lviv National Medical University Pekarska str., 69, Lviv, Ukraine, 79010 Postgraduate student Department of Toxicology and Analytical Chemistry

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












ScienceRise: Pharmaceutical Science

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 386
Cite : 93
2023 Impact : 0.132
ScienceRise: Pharmaceutical Science