User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 18
Farklı Rezin Simanlar ile Simante Edilen İndirekt Kompozit Restorasyonların Mikrosızıntı Miktarının Değerlendirilmesi
2021
Journal:  
Ege Üniversitesi Dişhekimliği Fakültesi Dergisi
Author:  
Abstract:

GİRİŞ ve AMAÇ: Bu çalışmanın amacı, Sınıf II indirekt kompozit resin restorasyonlarda, farklı adeziv simanların proksimal yüzeylerdeki mikrosızıntıya etkisinin değerlendirilmesidir. YÖNTEM ve GEREÇLER: Bu çalışmaya 24 adet çekilmiş, çürüksüz üçüncü molar diş dahil edildi. Standart Sınıf II kaviteler dişlerin hem distal hem de mesial yüzeylerinde ve mine-sement birleşiminden yukarıda olacak şekilde hazırlandı. Çalışma grupları 4 siman grubuna ayrıldı: GCem LinkAce (GCm) (GC, Japonya), Panavia F 2.0 (P) (Kuraray, Japonya), RelyX U200 (Rx) (3M ESPE, ABD), Superbond C&B (SB) (SunMedical, Japonya) ve kontrol (V) (Variolink II, Ivoclar Vivadent, Schaan, Liechtenstein). Her bir diş için mesial kavite çalışma grubu olacak şekilde ve distal kavite ise kontrol grubu olacak şekilde ayarlandı. Restorasyonlar indirekt kompozit materyalinden (Gradia; GC, Japonya) elde edildi ve kavitelere yapıştırıldı. Örneklere termosiklus uygulandı (5-55Cº,5000 döngü) ve sonrasında örnekler 24 saat boyunca %50 gümüş nitrat solüsyonunda bekletildi. Dişlerden mesio-distal olarak kesit alındı ve mikrosızıntı miktarları dijital görüntüleme yöntemi ile (24x; Leica optik mikroskop, Almanya) değerlendirildi. Kullanılan sıralı ölçek: 0-4 (0 = mikro sızıntı yok ve 4 = aksiyel duvar boyunca boya penetrasyonu). Her grup için ortalama değerler kaydedilmiş ve bu değerler Wilcoxon Signed Ranks testi kullanılarak istatistiksel olarak analiz edilmiştir. (alpha=0,05) BULGULAR: Tüm grupların oklüzal mikrosızıntı değerleri arasında anlamlı bir fark yoktur (GCm: 0; P: 0,17 ±.0,4; Rx: 0 ve SB: 0,17 ±.0,4) (P> 0,05). En az mikrosızıntı değerleri (μm ± SD) sırasıyla oklüzal (0.00; 0,00) ve gingival (0,83 ± 0,4; 0,50 ± 0,5) ksımlar için GCm ve Rx kendinden adezivli simanlar için kaydedildi. En yüksek mikrosızıntı SB ve P ile gingival kısımlarda (2,0 ± 1,4; 1,5 ± 0,84) kaydedildi ve fark diğer gruplara göre anlamlıdır. (P <0,05). TARTIŞMA ve SONUÇ: Test edilen kendinden adezivli dual-cure rezin simanlar uzun süreli mikrosızıntı stabilitesi sergilerken, self-cure rezin simanlar en yüksek mikrosızıntı değerleri göstermiştir.

Keywords:

Evaluation of the amount of microsecurity of the indirect composite restorations simulated with different resin shells
2021
Author:  
Abstract:

Introduction and Purpose: The purpose of this study is to evaluate the impact of different adhesive simans on microsisection on proximal surfaces in Class II indirect composite resin restorations. Method and Requirements: In this study, 24 untouched third molar teeth were included. Standard Class II cords are prepared so that they will be on both distal and mesial surfaces of the teeth and above the mine-sement combination. The study groups were divided into 4 siman groups: GCem LinkAce (GCm) (GC, Japan), Panavia F 2.0 (P) (Kuraray, Japan), RelyX U200 (Rx) (3M ESPE, USA), Superbond C&B (SB) (SunMedical, Japan) and Control (V) (Variolink II, Ivoclar Vivadent, Schaan, Liechtenstein). For each tooth, the messian cavity will be a working group and the distal cavity will be a control group. Restorations were obtained from indirect composite material (Gradia; GC, Japan) and attached to the caves. The samples were applied thermosic (5-55Co,5000 cycles) and then the samples were kept in a 50% silver nitrate solution for 24 hours. It was cut from the teeth as a mesio-distal and the microscopic amounts were assessed by the digital imaging method (24x; Leica optical microscope, Germany). The order scale used: 0-4 (0 = no micro leak and 4 = the penetration of paint along the axile wall). The average values for each group were recorded and these values were statistically analyzed using the Wilcoxon Signed Ranks test. (alpha=0,05) RESUMES: There is no significant difference between the oclusal microsisity values of all groups (GCm: 0; P: 0.17 ±.0.4; Rx: 0 and SB: 0.17 ±. It is 0.4 (P> 0.05 ) The minimum microsisance values (μm ± SD) were recorded for GCm and Rx self-adjective simans for oklusal (0.00; 0,00) and gingival (0,83 ± 0,4; 0,50 ± 0,5), respectively. The highest microsisance was recorded in gingival parts with SB and P (2,0 ± 1,4; 1,5 ± 0,84) and the difference is significant compared to other groups. (P is 0.05 ) CONTRIBUTION AND RESULTS: Tested self-adjustable dual-cury resin simens showed long-term microsisance stability, while self-cury resin simens showed the highest microsisance values.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Ege Üniversitesi Dişhekimliği Fakültesi Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 378
Cite : 496
Quarter
Basic Field of Health Sciences
Q3
151/222

Ege Üniversitesi Dişhekimliği Fakültesi Dergisi