User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 2
Çoklu-analit algılama amacıyla pasta-şeklinde fotonik kristal fiber bazlı yüzey plazmon rezonans algılayıcı
2022
Journal:  
Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi
Author:  
Abstract:

Bu çalışmada çoklu-analit algılama amacıyla, çift analit kanallı, fotonik kristal fiber (FKF) tabanlı yüzey plazmon rezonans (YPR) algılayıcı tasarlanmıştır. Plazmonik materyal olarak altın ve gümüş kullanılmıştır. Sayısal analizler Tam Vektörel-Sonlu Öge Yöntemi (TV-SÖY) kullanılarak yapılmıştır, ayrıca tasarlanan algılayıcı duyarlılık hesapları için spektral yöntemi kullanılmıştır. Sayısal analizler sonucu, en yüksek 6800 nm/RIU duyarlılığa ve 1.47x10-5 RIU çözünürlüğe ulaşılırken, sabit ve değişken analit kırılma indisleri için sırasıyla 3500 nm/RIU ve 3100 nm/RIU duyarlılık seviyelerine ulaşılmıştır.

Keywords:

Pie-shaped Photonic Crystal Fiber Based Surface Plasmon Resonance Sensor For Multi-analyte Sensing Purposes
2022
Author:  
Abstract:

In this study, the dual-channel photonic crystal fibre (PCF) based surface plasmon resonance (SPR) sensor has been proposed to sense multi-analyte. Gold and silver used as plasmonic layers. Full vectorial Finite Element Method (FV-FEM) have been used to perform numerical analysis. Also, the spectral interrogation method has been used to calculate the sensitivity of the proposed sensor structure. According to numerical results, the highest sensitivity levels are obtained as 6800 nm/RIU with 1.47x10−5 RIU, where the average sensitivities are calculated as 3500 nm/RIU and 3100 nm/RIU for fixed and variable refractive indices, respectively.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles


Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi

Field :   Mühendislik

Journal Type :   Ulusal

Metrics
Article : 1.968
Cite : 4.367
2023 Impact : 0.145
Pamukkale Üniversitesi Mühendislik Bilimleri Dergisi