User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 15
Preconcentration of trace amount Cu(II) by solid-phase extraction method usingactivated carbon-based ion-imprinted sorbent
2022
Journal:  
Turkish Journal of Chemistry
Author:  
Abstract:

In this study, preconcentration conditions of trace amounts of copper ions were investigated with solid-phase extraction (SPE) method by synthesizing activated carbon-based ion-imprinted sorbent (Cu(II)-IAC) with a novel and selective approach. Flame atomic absorption spectrometry (FAAS) was used for the determination of metal ions concentrations. For the characterization of the sorbents, scanning electron microscopy, energy dispersive X-ray (SEM/EDX) analysis, and Fourier transform infrared spectroscopy (FTIR) were used. Optimum conditions for the SPE procedure, various parameters such as pH value, eluent type and concentration, sample volume, sample flow rate, adsorption capacity, and selectivity were studied. The adsorption isotherm was analyzed by Freundlich and Langmuir isotherm, and the maximum adsorption capacity was found to be 142.9 and 312.5 mg/g for activated carbon-based nonimprinted (Cu(II)-non-IAC) and Cu(II)-IAC sorbents, respectively from the Langmuir isotherm. Limit of determination (LOD) and limit of quantification (LOQ) values were found to be 0.038 and 0.113 μg/L, respectively for Cu(II)-IAC sorbent, and the results were compared with the literature. The accuracy and validity of the proposed method were evaluated by the determination of Cu(II) ions from tap water samples and certified reference materials (CRMs) (soft drinking water ERML-CA021e and NIST 1643e) analysis. Good and quantitative recoveries were obtained for the spiked analysis.

Keywords:

2022
Author:  
0
2022
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Turkish Journal of Chemistry

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 2.410
Cite : 1.692
2023 Impact : 0.068
Turkish Journal of Chemistry