User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 20
 Downloands 5
Autonomous Neutron Facility for Detecting Fissile Nuclear Materials
2020
Journal:  
East European Journal of Physics
Author:  
Abstract:

The prospect of creating an autonomous neutron facility for the detection of fissile nuclear materials in samples, including those in confined volume, is discussed. It is proposed to obtain a reference field of thermal neutrons on the basis of a polyethylene moderator ball and a portable fast neutrons source, developed at NRC “Accelerator” NSC KIPT based of a continuous electrostatic accelerator of deuterons. The developed source of thermal neutrons is planned to be used to activate small objects and goods in order to identify substances prohibited for movement containing to find 233U, 235U and 239Pu in their composition. The prompt finding of fissile elements will indicate about an attempt to transport them illegally. A more thorough inspection can be carried out using special equipment after the detention of suspicious goods, citizens or vehicles. The possibility of detecting prompt fission neutrons is considered not only in the traditional way using a polyethylene moderator and proportional 3He detector, but also without application of any moderator using oxide or semiconductor scintillators. For detection fissile materials the method based on using the high-energy part of the γ-spectrum of fission fragments (greater than 4900 keV), as well, as the approach applied in the passive non-destructive analysis by the γ-line with Eg = 185.7 keV from 235U, are substantiated. It is shown that the proposed facility for the detection of fissile nuclear materials is able to determine the presence of isotopes 233U, 235U and 239Pu in tested objects and goods with the using non-destructive testing method.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












East European Journal of Physics

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 731
Cite : 76
2023 Impact : 0.115
East European Journal of Physics