User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 19
An Overview of Wearable Photoplethysmographic Sensors and Various Algorithms for Tracking of Heart Rates
2022
Journal:  
Engineering Proceedings
Author:  
Abstract:

: It is very challenging to estimate the accurate heart rate/beat during intense physical activities due to corruption of motion artifacts (MAs). However, it is difficult to reconstruct a clean signal and extract heart rate/beat from contaminated photoplethysmography (PPG) signals. It was also observed that various algorithms have been developed for use in the detection of heart rates during physical activities by reconstructing the contaminated PPG signals to clean PPG signals. Against this backdrop, an overview of the various algorithms was conducted with their results from various works. These results are such that the motion-tolerant adaptive algorithm indicated high agreement and high correlation of more than 0.98 for heart rate (HR) and 0.7 for pulse oxygen saturation (SpO 2) extraction between measurements by reference sensors and the algorithm. In addition, the distortion rates were reduced from 52.3% to 3.53%, at frequencies between 1 Hz and 2.5 Hz, when the two-dimensional active noise cancellation algorithm was applied representing daily motion such as walking and jogging. The correlation coefficient between the power spectral densities of the reference and reconstructed heart-rate time series was found to be 0.98, which showed that the spectral filter algorithm for motion artifacts and heart-rate reconstruction (SpaMA) method has a potential for PPG-based HR monitoring in wearable devices for fitness tracking and health monitoring during intense physical activities. The experimental result of the single-notch filter and ensemble empirical mode decomposition (NFEEMD) algorithm using the Pearson correlation was 0.992 which illustrated that the NFEEMD algorithm is not only suitable for HR estimation during continuous activities but also for intense physical activities with acceleration. Other algorithms suitable for HR estimation during physical activities include the time–frequency spectrum for the detection of motion artifacts (TifMA) algorithm, novel time-varying spectral filtering algorithm, noise-robust heart-rate estimation algorithm, real-time QRS detection algorithm, and many other algorithms in this regard.

Keywords:

0
2022
Author:  
Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Engineering Proceedings

Journal Type :   Uluslararası

Engineering Proceedings