KONUT TİPİ BİNALARDA SOĞUTMA YÜKÜNÜN OPTİMUM YALITIM KALINLIĞINA ETKİSİ
2020
Journal:  
Isı Bilimi ve Tekniği Dergisi
Author:  
Abstract:

Bu çalışmanın amacı, Türkiye’deki konut tipi binalar için soğutma yükü etkisi altında optimum yalıtım kalınlığının (U-değerlerini) ömür maliyet analizi yapılarak belirlenmesi ve elde edilen sonuçlara göre TS 825 “Binalarda Isı Yalıtım Kuralları” standardında soğutma yükünün de hesaplamalara katılması gereken Derece Gün (DG) bölgelerinin tespit edilmesidir. Alan/Hacim (A/V) oranı 0,40 m-1 olan 5 katlı bir apartman binası referans bina olarak alınmıştır. Binaların yıllık enerji ihtiyaçları, TS EN ISO 13790 standardına göre hesaplanmıştır. Toplam maliyeti temel alan ömür maliyet analizi 30 yıllık bir kullanım ömrü için yapılmıştır. Optimum yalıtım kalınlıkları iklim bölgelerine göre; cephe için 0 cm ile 4 cm, tavan için 0 cm ile 7,5 cm, taban için 0 ile 2,3 cm arasında hesaplanmıştır. Sonuç olarak, TS 825 standardında belirtilen DG1 ve DG2 bölgelerinde soğutma yükünün optimum yalıtım kalınlığı hesaplarına dahil edilmesi gerektiği belirlenmiştir. DG1 ve DG2 bölgelerine göre daha soğuk iklim şartlarının etkili olduğu DG3 ve DG4 bölgelerinde soğutma yükünün optimum yalıtım kalınlığını etkilemediği sonucuna varılmıştır.

Keywords:

The Effect Of Cooling Load On Optimum Insulation Thickness In Residential Buildings
2020
Author:  
Abstract:

The main objective of this study is to determine the optimum insulation thickness of residential buildings in Turkey, under the influence of cooling loads by life cycle cost analysis (LCCA) and to specify the Degree Day (DG) regions that the cooling load should also be included in the calculations in the TS 825 “Heat Insulation Rules in Buildings” standard. A 5-storey apartment building with an Area/Volume ratio (A/V) of 0,40 m-1 is taken as a reference building. The annual energy requirements of the reference building for cooling loads are calculated according to TS EN ISO 13790 standard. Life-cycle cost analysis based on the total cost approach is performed for a period of 30 years. Optimum insulation thicknesses based on climate zones are calculated between 0 cm and 4 cm for wall, 0 cm and 7,5 cm for ceiling, 0 cm and 2,7 cm for floor. As a result, it has been determined that cooling load should be included in the optimum insulation thickness calculations in the DG1 and DG2 regions specified in the TS 825 standard. It is concluded that the cooling loads don’t affect the optimum insulation thickness in DG3 and DG4 regions where the cooler climate is more effective than DG1 and DG2 regions

Keywords:

Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles




Isı Bilimi ve Tekniği Dergisi

Field :   Mühendislik; Fen Bilimleri ve Matematik

Journal Type :   Ulusal

Metrics
Article : 103
Cite : 6
2023 Impact : 0.024
Isı Bilimi ve Tekniği Dergisi