User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 12
 Downloands 3
Importance of Femoral Access Method in Predicting the Development of Contrast Induced Nephropathy after Transfemoral Transcatheter Aortic Valve Implantation
2016
Journal:  
Koşuyolu Heart Journal
Author:  
Abstract:

Introduction: Transcatheter aortic valve implantation (TAVI) is more reliable than surgical valve replacement for high-risk or inoperable aortic stenosis patients. In this study, we aimed to investigate the effects of different femoral access methods on the development of vascular complications and contrast-induced nephropathy (CIN) after transfemoral (TF)-TAVI. Patients and Methods: In total, 110 patients (aged 78.9 ± 12.2 years; 55 females) who underwent aortic valve replacement by TF-TAVI between June 2013 and April 2015 were included in the study. CIN was defined as an absolute increase in serum creatinine level of > 0.5 mg/dL or a relative increase of > 25% within 48-72 h after TF-TAVI. The patients were classified into two groups according to the femoral access methods: surgical cut-down (SCD) and vascular closure device (VCD) groups. Results: The amount of contrast medium (CM; p< 0.001) and the incidence of CIN (p= 0.038) were higher in the VCD group. Baseline glomerular filtration rate (GFR), baseline creatinine, Mehran score and CM were determined as the predictive factors of CIN development. Receiver operating characteristic analysis revealed that CM, which may predict the development of CIN, was determined as 178.5 mL, and GFR, which may predict the development of CIN, was determined as 48.9 mL/dk/1.73 m2. Conclusion: It may be preferred to perform the femoral arterial procedure using the SCD method instead of VCD in TAVI patients whose GFR is < 48.9; the use of CM may increase due to various reasons.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Koşuyolu Heart Journal

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 578
Cite : 170
Koşuyolu Heart Journal