User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 25
 Downloands 3
Sustainable Hybrid Design to Ensure Efficiency and Air Quality of Solar Air Conditioning
2023
Journal:  
Engineering, Technology & Applied Science Research
Author:  
Abstract:

Abstract This research work aims to investigate and subsequently optimize the operating parameters that affect thermal comfort and indoor air quality in the school environment. The proposed design uses a coupling between solar ventilation and the absorption chiller-air conditioning. The heating tower of an adsorption chiller connected to an air conditioning system can be driven by the waste heat from a solar ventilation (exhausted hot air) system thank to this linkage. In order to simulate variables like the velocity magnitude distribution in the air-conditioned room, mathematical modeling is numerically executed. Air temperature evolution along the height of the conditioned room in the mid-length and the air velocity evolution along the length of the conditioned room in the mid-height are studied. According to the numerical simulation results, the inlet air temperature soars as the inlet air velocity rises. Inlet air velocities of 0.05m/s, 0.5m/s, and 1m/s are correlated with inlet air temperatures of 20.7°C, 21.2°C, and 21.3°C, respectively. We conclude that an inlet air velocity in the order of 1m/s (in relation to a maximized air change rate) is in agreement with the general ASHRAE standards for indoor air quality in the case of the school environment, coupled with the essential need to limit as much as possible the spread of viruses.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Engineering, Technology & Applied Science Research

Journal Type :   Uluslararası

Metrics
Article : 1.845
Cite : 2.898
2023 Impact : 0.733
Engineering, Technology & Applied Science Research