User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
  Citation Number 1
 Views 13
Energy, exergy analysis and optimization of insulation thickness on buildings in a low-temperature district heating system
2023
Journal:  
Journal of Thermal Engineering
Author:  
Abstract:

In the study, energy and exergy analysis of the buildings on a campus in Turkey are conducted by using actual operating data and taking measurements in the district heating system as a case study. The energy and exergy demands, losses that stem from all buildings are calculated according to average daily outdoor temperature data. Due to the high heat losses in the buildings, determining the optimal insulation thickness for the exterior wall should be investigated. Therefore, optimal insulation thicknesses, energy savings, fuel consumptions and payback periods of the insulation material on the exterior wall of the building are examined by using Life Cycle Assessment and P1–P2 method for natural gas. Optimal insulation thicknesses are calculated for different insulation materials such as XPS, glass wool, rock wool and EPS for the climatic regions (HDD=800–4250°C days). According to average exergy losses from the building components per unit area, the average total exergy loss is calculated as 2.39×10-2 kW/m2.year and 1.42×10-3 kW/m2 (5.92%) of this loss stems from the exterior walls, 1.93×10-3 kW/m2 (8.07%) from the floors, 7.37×10-4 kW/m2 (3.08%) from the roofs, 1.58×10-2 kW/m2 (65.99%) from the windows and doors, 4.04×10-3 kW/m2 (16.92%) from the ventilation with infiltration. Energy requirement values of the building are found between 2.68–25.70 kWh/m3 towards from the warmest to the coldest climatic region for the uninsulated wall. In the un-insulated state, fuel consumption varies between 1.93-18.48 m3/m2 from the warmest to the coldest region. The optimal insulation thickness values of the building’s exterior wall are calculated as between 2.3–10.0 cm according to different climatic regions. In-state of exterior wall insulation of 3 cm, fuel consumption decreases by 46.63%–53.46% compared to different insulation materials and climatic regions compared to the un-insulated state.

Keywords:

0
2023
Author:  
Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles








Journal of Thermal Engineering

Field :   Mühendislik

Journal Type :   Uluslararası

Metrics
Article : 493
Cite : 243
2023 Impact : 0.05
Journal of Thermal Engineering