User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 8
Investigation of Outdoor Air Temperature Effects on Heat Recovery in Cross Flow Heat Exchanger
2023
Journal:  
Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Author:  
Abstract:

A heat recovery device was designed and manufactured to provide air-to-air heat transfer by using a cross-flow heat exchanger on the pipe bundles. For this purpose, different cold air inlet temperature values and the temperature values of high temperature hot exhaust gases in the tube bundle heat exchanger were determined as operating parameters. According to the temperature increase of the cold air entering the heat exchanger; The kinematic viscosity values of the air increased and the maximum Reynolds number in the flow state of the air passing through the test heat exchanger was decreased. The average Nusselt numbers and average air convection coefficients in the flow of air decreased according to the temperature increase of the cold air. According to the temperature increase of the cold air entering the heat exchanger, both the analytical and experimental outlet temperature values of the cold air leaving the heat exchanger increase very close to each other. With this increase, the amount of heat transferred from the fluid to the fluid in the heat exchanger decreases. While the temperature value of the cold air entering the heat exchanger increases, the temperature difference value of the advancing air from the beginning to the outlet (ΔT= Ts – Ti) decreases. Due to this decrease, a decrease was observed in the amount of heat transfer.

Keywords:

0
2023
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles






Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 829
Cite : 1.101
2023 Impact : 0.011
Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi