User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 17
 Downloands 1
İMPLANT ÜSTÜ OVERDENTURE PROTEZLERDE TUTUCU BAŞLIK DEFORMASYONUNA ALTERNATİF BİR ÇÖZÜM YÖNTEMİ: BİR OLGU SUNUMU
2019
Journal:  
Current Research in Dental Sciences
Author:  
Abstract:

İmplant üstü overdenture protezler retansiyon ve stabiliteye olumlu katkılarından dolayı tam dişsiz hastaların yaşam kalitelerini artırmakta ve günümüzde standart bir tedavi protokolü olarak kabul edilmektedir. İmplant üstü overdenture protezlerde implantların üzerine topuz başlı ataşman, locator ataşman, barlı eklem veya mıknatıs gibi mekanizmalar yerleştirilerek tutuculuk sağlanmaktadır. Protezin içine kullanılan bağlantı mekanizmasına göre tutucu başlıklar yerleşti- rilmektedir. İmplant üstü overdenture protezlerin uzun dönem başarıları değerlendirildiğinde en sık karşılaşılan mekanik problemin tutucu başlıkların plastik yapıla- rındaki deformasyona bağlı retansiyon kaybı olduğu bilinmektedir. Çoğunlukla lastik yapıların yenilenmesi ile tutuculuk yeniden sağlanabilmektedir. Bu olgu sunumunda implant üstü overdenture protezindeki tutuculuk kaybı nedeniyle kliniğimize başvuran bir hastanın şikayetlerinin giderilmesine yönelik uygulanan alternatif yöntem hakkında bilgi verilmiştir. Anahtar Kelimler: Overdenture, implant, topuz başlı ataşman AN ALTERNATIVE SOLUTION METHOD FOR DEFORMATION OF RETENTIVE CAPS IN IMPLANT SUPPORTED OVERDENTURE PROSTHESIS: A CASE REPORT Nowadays implant supported overdenture dentures are accepted as a standard treatment protocol due to improving life quality of edentulous patients with their positive contribution on retention and stability. Some mechanisms such as ball attachment, locator attachment and magnet retained system might be used for providing retention of implant supported overdenture prosthesis. Retainer caps are placed according to the retention mechanism used in the prosthesis. It is known that the most common mechanical problem was loss of retention due to deformation of the plastic structures when the long-term success of implant overdenture prosthesis evaluated. Generally the retention can be restored again with renovation of plastic structures. In this case report information was provided on an alternative method applied for the removal of the patient's complaints due to loss of retention of implant supported overdenture prosthesis. Keywords: Overdenture, implant, ball attachment

Keywords:

Implant Overdenture Protheses A Alternative Solution to the Prison Deformation: A Presentation of Events
2019
Author:  
Abstract:

Overdenture on-implant proteins improve the quality of life of full-dental patients due to their positive contribution to retention and stability and are now considered a standard treatment protocol. In the overdenture prothes on the implants, holding is provided by placing mechanisms such as top head attachment, locator attachment, bar joint or magnet. According to the connective mechanism used in the protein, the holding headings are placed. When the long-term achievements of overdenture implants are assessed, it is known that the mechanical problem that we encounter is the loss of retention due to the deformation of the plastic-made heads. It is often possible to restore the retention with the renovation of the tyres. The presentation of this fact provides information about the alternative method used to remove the complaints of a patient who applies to our clinic due to the loss of retention in the overdenture protein on the implant. Keywords: Overdenture, implant, ball head adhesive AN ALTERNATIVE SOLUTION METHOD FOR DEFORMATION OF RETENTIVE CAPS IN IMPLANT SUPPORTED OVERDENTURE PROSTHESIS: A CASE REPORT Nowadays implant supported overdenture dentures are accepted as a standard treatment protocol due to improving life quality of edentulous patients with their positive contribution on retention and stability. Some mechanisms such as ball attachment, locator attachment and magnet retained system might be used to provide retention of implant supported overdenture prosthesis. Retainer caps are placed according to the retention mechanism used in the prosthesis. It is known that the most common mechanical problem was loss of retention due to deformation of the plastic structures when the long-term success of implant overdenture prosthesis evaluated. Generally the retention can be restored again with the renovation of plastic structures. In this case report information was provided on an alternative method applied for the removal of the patient's complaints due to loss of retention of implant supported overdenture prosthesis. Keywords: overdenture, implant, ball attachment

Keywords:

0
2019
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Current Research in Dental Sciences

Journal Type :   Ulusal

Metrics
Article : 1.431
Cite : 2.157
Current Research in Dental Sciences