User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 10
Biomechanical comparison of fixation of two-part osteoporotic neck fracture of the proximal humerus using uni-planar and multi-planar Kirschner wire
2009
Journal:  
Joint Diseases and Related Surgery
Author:  
Abstract:

Objectives: The stability and effectiveness of uni-planar Kirschner wire (K-wires) was compared to multi-planar K-wires osteosynthesis combined with tension band wiring for fixation of two-part osteoporotic surgical neck fracture of the proximal humerus. Materials and methods: Two groups each with eight cadaveric elderly (mean age 72.6; range 70 to 80 year) frozen human humeri were used in the study. Transverse osteotomy of the proximal humerus was performed using a thin oscillating saw. The first group (group A) was fixed using two anterograde smooth K-wires, sent from lateral cortex, combined with tension band wiring. The second group (group B) was fixed using multi-planar (anterograde and retrograde) four smooth K-wires combined with tension band wiring on the lateral cortex. Biomechanical tensile properties for 3 mm displacement (gap load) and maximum load were assessed. Results: The mean value for the gap load was 1045.0±45.4 N (Newton) for group A and 1238.1±115.8 N for group B. Gap load values of groups were similar (p=0.01). The maximum load was 1261.8±52.4 N in group A and 1471.1±107.3 N in group B. The maximum load values were statistically higher in the multiplanar fixation technique (group B) when compared to that of the uniplanar fixation technique (group A), (p=0.004). Conclusion: Fixation in osteoporotic two-part surgical neck fractures of the proximal humerus using multiplanar K-wires combined with tension band wire provides substantially more effective stability compared to that of uniplanar fixation.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Joint Diseases and Related Surgery

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 295
Cite : 22
2023 Impact : 0.005
Joint Diseases and Related Surgery