User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 44
BİR ISI DEĞİŞTİRİCİSİNDE FARKLI SU-ETİLEN GLİKOL KARIŞIMI KULLANIMININ ISI TRANSFER PERFORMANSINA ETKİLERİNİN DENEYSEL ANALİZİ
2021
Journal:  
Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi
Author:  
Abstract:

Bu çalışmada bir otomobil radyatöründe akışkan olarak farklı karışım oranlarında su-etilen glikol karışımının kullanımının, radyatörün ısı transfer performansı üzerindeki etkileri deneysel olarak incelenmiştir. Bu amaçla, su içerisine hacimsel olarak etilen glikol ilave edilmiş ve etilen glikolün hacimsel oranı %0, %25, %50, %75 ve %100 olduğu durumlar için deneyler gerçekleştirilmiştir. Tüm bu karışım oranları için, akışkan giriş sıcaklığı 40-80 °C aralığında, akışkan giriş debisi 10-22 l/dk aralığında ve soğutma hava ise 1-4 m/s aralığında değiştirilmek üzere toplam 300 adet deney gerçekleştirilmiştir. Yapılan deneyler sonucunda etilen glikolün karışım oranının artması durumunda radyatörden gerçekleşen ısı transferinin azaldığı gözlemlenmiştir. Ancak soğutma hava hızı, akışkanın giriş debisi ve radyatör giriş sıcaklığı arttıkça, gerçekleşen ısı transferinde de artış olduğu belirlenmiştir. Dolayısıyla radyatörlerde su yerine su-etilen glikol karışımının kullanılması durumunda, radyatör akışkanının donma nokta sıcaklığının düşürülmesi sağlanırken, radyatörün ısı transfer performansının olumsuz olarak etkilendiği gözlemlenmiştir.

Keywords:

Experimental Analysis Of The Effects Of Using Different Water-ethylene Glycol Mixture Rates On Heat Transfer Performance In A Heat Exchanger
2021
Author:  
Abstract:

In this study, the effects of using different water-ethylene glycol mixture rates on heat transfer performance put in an automobile radiator as a liquid is experimentally analysed. Ethylene glycol is added in water volumetrically and experiments are conducted for 0%, 25%, 50%, 75% and 100% volumetric ratio of ethylene glycol. For all these mixture rates, 300 experiments are conducted for fluid inlet temperature between 40-80 °C, fluid inlet flow rate between 10-22 l/min and cooling air between 1-4 m/s. As a result of the experiments, it is observed that as ethylene glycol mixture ratio passing from the radiator increased, heat transfer decreased. However, as cooling air velocity, fluid inlet flow rate and radiator inlet temperature increased, heat transfer increased as well. When water-ethylene glycol mixture is used in the radiator instead of water, it is observed that radiator fluid freezing temperature decrease and radiator heat transfer performance is negatively impacted.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi

Field :   Mühendislik

Journal Type :   Uluslararası

Metrics
Article : 495
Cite : 981
Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi