User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 16
 Downloands 3
Pulse-Galvanic Skin Response Analysis with Multiple Sensor Device Design
2021
Journal:  
Akıllı Sistemler ve Uygulamaları Dergisi
Author:  
Abstract:

In this study, the development of a low-cost electronic card-based medical device measuring and recording patient data was described via non-invasive methods. Both the descriptive statistical analysis and the regression model was performed from the pulse and galvanic skin response (GSR) from the volunteer' data. It is important to measure and record different data simultaneously with multiple sensors from the patient during the treatment, medical operation and care periods of the patients. The data measured from the designed device was evaluated for the patient's position, GSR, the respiration rate, the blood oxygen content, and the heart rate. The designed measurement and recording device were implemented with an embedded system-based microcontroller card. The designed device might provide for monitoring and recording data with led display, serial port, microSD card or internet of things.

Keywords:

Pulse-Galvanic Skin Response Analysis with Multiple Sensor Device Design
2021
Author:  
Abstract:

In this study, the development of a low-cost electronic card-based medical device measuring and recording patient data was described via non-invasive methods. Both the descriptive statistical analysis and the regression model were performed from the pulse and galvanic skin response (GSR) from the volunteer' data. It is important to measure and record different data simultaneously with multiple sensors from the patient during the treatment, medical operation and care periods of the patients. The data measured from the designed device was evaluated for the patient's position, GSR, the respiration rate, the blood oxygen content, and the heart rate. The designed measurement and recording device were implemented with an embedded system-based microcontroller card. The designed device might provide for monitoring and recording data with led display, serial port, microSD card or internet of things.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Akıllı Sistemler ve Uygulamaları Dergisi

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 140
Cite : 12
2023 Impact : 0.041
Akıllı Sistemler ve Uygulamaları Dergisi