User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 10
 Downloands 2
Effect of Immersion in Disinfectants on Cyclic Fatigue Resistance of Nickel-Titanium Instruments: An in Vitro Study
2023
Journal:  
Frontiers in Dentistry
Author:  
Abstract:

Objectives: The current study aimed to assess the cyclic fatigue resistance of two nickel-titanium (NiTi) rotary files after immersion in 5% sodium hypochlorite (NaOCl) and Deconex. Materials and Methods: In this in vitro study, 90 new M3 Pro Gold size 25.06 and size F2 SP1 files were tested. Forty-five files of the same brand were randomly distributed into three groups (n=15) and submitted to the following immersion protocol for 5 minutes at room temperature: no immersion (control group), immersion in 5% NaOCl, and immersion in Deconex. The cyclic fatigue resistance of the files was then measured in a custom-made tester. Two-way ANOVA was applied to compare the cyclic fatigue resistance of SP1 and M3 NiTi rotary files based on the type of disinfectant solution. Post-hoc LSD test was used for pairwise comparisons and P<0.05 was considered significant. Results: Two-way ANOVA indicated a significant difference in the mean cyclic fatigue resistance of M3 and SP1 NiTi rotary files. The M3 files immersed in NaOCL displayed the lowest and the SP1 files immersed in Deconex showed the maximum cyclic fatigue resistance. The effect of type of disinfectant solution (P<0.001) and type of NiTi file (P<0.001) on cyclic fatigue resistance was statistically significant.   Conclusions: The cyclic fatigue resistance of NiTi rotary instruments can be affected by immersion in disinfectants, and the specific type of file and disinfectant used will ultimately determine the extent of this impact.

Keywords:

0
2023
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Frontiers in Dentistry

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 854
Cite : 372
Frontiers in Dentistry