User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 20
Measurement of Ocular Pulse Amplitude Using Dynamic Contour Tonometry and the Influence of Central Corneal Thickness, Axial Lenght and Anterior Chamber Depth on the Measurements - Original Article
2007
Journal:  
Türk Oftalmoloji Dergisi
Author:  
Abstract:

Purpose: To investigate the effects of age, sex, intraocular pressure (IOP), central corneal thickness (CCT), corneal curvature, anterior chamber depth (ACD) and axial length on OPA measurements using dynamic contour tonometer (DCT) in healthy subjects. Materials Methods: Fifty-three eyes of 53 healthy individuals were included in this prospective study. After keratometric measurements, OPA and IOP were measured using Pascal DCT under topical anesthesia. The CCT was determined with the aid of ultrasonic pachymeter. After that, ACD and axial length of the subjects were measured by A scan ultrasonography. Pearson correlation analysis was used to determine the association between OPA and other parameters. Results: The mean age of 53 subjects (34 female, 19 male) who were included in the study was 52,68 ± 8,29 years. Mean OPA was 2,81 ± 1,01 mm Hg. Mean IOP was 15,89 ± 2,39 mm Hg, corneal curvature was 7,80 ± 0,23 mm, CCT was 556,30 ± 32,80 µm, ACD was 2,91 ± 0,32 mm and axial length was 23,14 ± 1,10 mm. There was no correlation between OPA values and age, CCT or ACD of the subjects (p>0.05). There were significant negative correlations between OPA and axial length (p Conclusion: OPA values are found to be correlated with axial length, corneal curvature and IOP. There is no correlation between OPA and CCT. Since OPA measurements using DCT were less effected by corneal biomechanical properties, it gives more reliable information about ocular blood flow.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Türk Oftalmoloji Dergisi

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 191
Cite : 15
2023 Impact : 0.007
Türk Oftalmoloji Dergisi