User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 26
 Downloands 5
One-year outcomes of novel BioMime Morph tapered stent in long and multiple coronary artery lesions
2021
Journal:  
The Anatolian Journal of Cardiology
Author:  
Abstract:

Objective: Even with the immense progress achieved in the field of percutaneous coronary interventions (PCIs), treatment of diffuse long atherosclerotic coronary artery disease continues to remain a challenge for durable outcomes. The downstream reduction in diameter along the lesion length of a coronary artery may compel the cardiologist to use either 2 overlapping stents of different diameters or a single long stent leading to stent-vessel mismatch at the edges. Recently, Meril Life Sciences Pvt. Ltd., India, has introduced a long-tapered sirolimus-eluting stent (SES) system, BioMime Morph, which conforms to the normal tapered geometry of coronary arteries along with adequate lesion coverage. In this study, we aimed to provide real world experience regarding the safety and efficacy of the BioMime Morph SES over a follow-up of one year. Methods: This was a single center, retrospective study involving 172 participants who underwent PCI with the BioMime Morph SES. Mean length of the target lesion was 34.4±10.4 mm, and mean stent length was 53.2±8.7 mm. The most frequent revascularized vessel was the left anterior descending artery (LAD) in 97 lesions (54.4%). Results: Major adverse cardiac events (MACE) (defined as a composite of target vessel myocardial infarction, target lesion revascularization, and death due to a cardiac cause) at 1, 6, and 12 months were seen in 4 (2.3%), 7 (4.0%), and 8 (4.7%) patients, respectively. Overall, 5 cardiac deaths and 2 definite stent thrombosis were observed in the study. Conclusion: The study suggests that the novel BioMime Morph SES is an effective and a safe option for PCI in the treatment of long diffuse atherosclerotic lesions.

Keywords:

2021
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles












The Anatolian Journal of Cardiology

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 507
Cite : 218
2023 Impact : 0.101
The Anatolian Journal of Cardiology