NaI(Tl) detektörü için enerji kalibrasyonunun ve enerji çözünürlüğünün elde edilmesi
2017
Journal:  
Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Author:  
Abstract:

Nükleer radyasyonun enerji ölçümlerinde spektrometrenin karakteristiklerini belirlemek son derece önemlidir.  Gelen gama ışınlarının enerjisine bağlı olarak, detektörden elde edilen pulslar, puls yüksekliği analizi (Puls Height Analysis-PHA) metoduyla çok kanallı analizörde (Multi Channel Analyzer-MCA) gama spektrumları olarak gözlenir. MCA’de kanal başına düşen gama enerjilerini belirlemek için detektörün enerji kalibrasyonunu ve birbirine yakın enerjili gama-ışınlarını ayırt etme yeteneği olan enerji çözünürlüğünü bilmek gereklidir. Bu çalışmada, 137Cs, 60Co, 22Na ve 133Ba standart gama ışını kaynaklarının puls yüksekliği spektrumları ölçülerek gama ışınları için yüksek verime sahip olan NaI(Tl) detektörünün enerji kalibrasyonu ve enerji çözünürlüğü elde edilmiştir.

Keywords:

Obtaining energy calibration and energy resolution for the NaI(Tl) detector
2017
Author:  
Abstract:

In the energy measurement of nuclear radiation, determining the characteristics of the spectrometer is extremely important.  Depending on the energy of the coming gamma rays, the pulses obtained from the detector are observed as gamma spectra in the multi-channel analyzer (MCA) by the pulse height analysis (PHA) method. In MCA, it is necessary to know the energy calibration of the detector and the energy resolution, which is the ability to distinguish the energy gamma rays close to each other, to determine the gamma energies falling per channel. In this study, the energy calibration and energy resolution of the NaI(Tl) detector, which has high performance for gamma rays, was achieved by measuring the pulse height spectrum of the 137Cs, 60Co, 22Na and 133Ba standard gamma radiation sources.

Keywords:

Citation Owners
Attention!
To view citations of publications, you must access Sobiad from a Member University Network. You can contact the Library and Documentation Department for our institution to become a member of Sobiad.
Off-Campus Access
If you are affiliated with a Sobiad Subscriber organization, you can use Login Panel for external access. You can easily sign up and log in with your corporate e-mail address.
Similar Articles










Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi

Field :   Eğitim Bilimleri; Fen Bilimleri ve Matematik; Mühendislik

Journal Type :   Ulusal

Metrics
Article : 874
Cite : 2.500
2023 Impact : 0.115
Quarter
Basic Field of Science and Mathematics
Q3
69/135

Basic Field of Educational Sciences
Q3
167/239

Basic Field of Engineering
Q3
57/114

Balıkesir Üniversitesi Fen Bilimleri Enstitüsü Dergisi