User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 ASOS INDEKS
 Views 7
Surface and build-up region dose characteristics for high energy photons
2006
Journal:  
Turkish Journal of Oncology
Author:  
Abstract:

OBJECTIVES The surface doses of high energy photon beams show variability depending on the design of the treatment machine. Especially while using bolus that has a direct effect on surface and build-up region doses, defining correctly in the treatment planning system used for patient treatment is very important. It needs to be measured for each radiation beam used. In this study, the dose change of high energy beams surface and build-up region that were used in I.U. Oncology Institute according to the field size and the skin source distance were investigated. METHODS Co-60 teletherapy equipment, Orion 4 (MV), Saturn 42 (6-15 MV) high energy x-rays were used. Measurements were made for different field sizes and source skin distances by using Marcus–type parallel plate ion chamber at water equivalent solid phantom, at surface and build-up region. Measured surface and build-up doses were installed to CMS XiO treatment planning system. RESULTS As a result of this study, the surface dose increased linearly as the field size increased and the maximum dose point was moved toward the surface by 1-2 mm as predicted. Surface doses for a 10x10 cm field size are 24.3%, 17.4%, 12.6% and 10.2% respectively for Co-60, 4MV, 6MV and 15MV. With the increase in skin source distance, a decrease in surface doses is observed. CONCLUSION The use of correct information is achieved by downloading surface doses measured for different field sizes to the treatment planning system.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles












Turkish Journal of Oncology

Field :   Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 215
Cite : 8
Turkish Journal of Oncology