User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 7
A Simulation and Experiment on the Optimization Design of an Air Outlet Structure for an Air-Assisted Sprayer
2023
Journal:  
Agriculture
Author:  
Abstract:

: In response to the issues of low-velocity zones and non-uniform jet velocity distribution in the airflow field of traditional air-assisted orchard sprayers, an arc-shaped air outlet suitable for axial-flow air-assisted systems is designed. This article employs the method of CFD numerical simulation and experimental verification to compare and analyze the internal flow field of the air-assisted system and validates the reliability of the numerical simulation results through calculation error and chi-square test. The wind speed of the cross-section is measured at different distances from the outlet, and the distribution characteristics of the outflow field wind speed before and after the structural optimization of the air-assisted system are compared. The horizontal distribution of fog droplets is collected using a fog collection chamber. The experimental results show that the design of the arc-shaped outlet increases the average wind speed of the annular outlet from 14.95 m/s to 18.20 m/s and reduces the proportion of low-speed area from 20.83% to 0.71%. When the rounded corner radius of the air outlet is 50 mm, optimal parameters are attained. The maximum error between the simulated and experimental values is 9.52%. At a significance level of 0.05, the χ 2 value is 0.252, indicating that the simulated values follow the distribution of the actual measurement values. On the cross-sections located at distances of 0.5, 0.75, 1, 1.25, and 1.5 m from the air outlet, the wind speed distribution with no arc-shaped air outlets exhibits a “low left and high right” type, tending to shift towards the right as a whole. Fog droplets also display a drift tendency towards the right side. The wind speed distribution with arc-shaped air outlets shows a symmetric “high in the middle and low on the sides” type. Fog droplets concentrate in the central position. The optimized air-assisted system can reduce the air field’s low-flow area, increase the airflow distribution uniformity, improve the average wind speed at the outlet, and decrease fog droplet drift. This provides a reference for the structural design of air-assisted systems in current orchard sprayers of the same type.

Keywords:

0
2023
Journal:  
Agriculture
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Agriculture

Journal Type :   Uluslararası

Metrics
Article : 9.835
Cite : 6.423
2023 Impact : 0.04
Agriculture