 Downloands 1
BİYOLOJİK OLARAK ARITILMIŞ TEKSTİL ENDÜSTRİSİ ATIKSULARININ LABORATUVAR ÖLÇEKLİ ÇAPRAZ AKIŞ SİSTEMİNDE TERS OSMOZ MEMBRANLARI KULLANILARAK GERİ KAZANIMI
2019
Journal:  
Uludağ University Journal of The Faculty of Engineering
Author:  
Abstract:

Bu çalışmanın amacı; üç farklı ters osmoz membranının gerçek tekstil endüstrisi atıksularının arıtımındaki performanslarının değerlendirilmesi ve kıyaslanmasıdır. Çalışmada tekstil endüstrisi atıksularını arıtan gerçek ölçekli atıksu arıtma tesisi çıkış suları kullanılmış olup, membran performansları KOİ, renk, iletkenlik ve membran akısı açısından değerlendirilmiştir. Çalışmada 10 saatlik filtrasyon çalışmalarında çapraz akışlı filtrasyon düzeneği ile B400FR, B400HR ve BW30 membranları test edilmiştir. Aynı basınçta yapılan çalışmada, en yüksek permeabilite değerini (3,45±0,12 LMH/bar) ve en düşük akı kaybını (%69) B400HR membranı verirken, akıdaki en yüksek azalma (%82) BW30 membranında gözlemlenmiştir. Kullanılan atıksu 4570±130 µS/cm iletkenlik, 188±2 Pt-Co renk ve 35±2 KOİ konsantrasyonlarına sahip olup, test edilen tüm membranlar için süzüntü KOİ değeri 10 mg/L'nin altına düşürülmüş olup, en iyi KOİ giderim performansını B400FR membranı göstermiştir. Ortalama iletkenlik giderimi ise tüm membranlar için %92 değerinin üzerinde olup, B400FR, B400HR ve BW30 için sırasıyla %96, 94 ve 92 değerlerindedir. Benzer şekilde tüm membranlar için renk giderimi %99 un üzerinde gerçekleşmiştir. Elde edilen sonuçlarla süzüntü suyunun aynı endüstride geri kullanımı mümkündür.

Keywords:

Biologically invented textile industry atics laboratory measurement diameter flow system with the use of TERS OSMOZ membranes
2019
Author:  
Abstract:

The aim of this study is to evaluate and compare the performance of the three different reverse osmosis membranes in the processing of real textile industry waste. The study used real-scale waste treatment facility output waters that cleanse textile industry waste, and membrane performance was evaluated in terms of COI, color, conductivity and membrane flow. The study tested the B400FR, B400HR and BW30 membranes with cross-flow filtration arrangements in 10 hour filtration studies. In the same pressure study, the highest permeability value (3.45±0.12 LMH/bar) and the lowest flow loss (69) were given to the B400HR membrane, while the highest flow decrease (82) was observed in the BW30 membrane. The waste used has 4570±130 μS/cm conductivity, 188±2 Pt-Co color and 35±2 COI concentrations, the flow COI value for all the tested membranes is reduced to below 10 mg/L, and the B400FR membrane has shown the best COI discharge performance. The average conductivity output is above the value of 92% for all membranes, with the value of 96, 94 and 92% for B400FR, B400HR and BW30 respectively. Similarly, the color discharge for all membranes occurred above 99%. With the results obtained, the reuse of the water is possible in the same industry.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Uludağ University Journal of The Faculty of Engineering

Field :   Mühendislik

Journal Type :   Ulusal

Metrics
Article : 1.004
Cite : 2.968
2023 Impact : 0.114
Uludağ University Journal of The Faculty of Engineering