User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 17
 Downloands 4
Analyze Performance of Heat Exchanger by using Manual Calculation and Cfd Simulation
2021
Journal:  
Natural Volatiles and Essential Oils
Author:  
Abstract:

In this research would be planned to optimize the utilization of boiler exhaust gas by adding a heat exchanger to the chimney to heat the incoming water to the boiler. The types of heat exchangers are very diverse and each is designed to meet specific needs, but the shell and tube type is by far the most widely used type due to its relatively simple construction and reliability because it can be operated with several types of working fluids. Optimization of the design of this heat exchanger was done by full factorial method using four independent variables, namely diameter, length, distance between pipes and pipe angles with three levels of experimentation so that 81 calculated data were obtained. The result of full factorial optimization obtained the highest value of design displacement coefficient (Ud) of 354 W/m2oK.This condition is obtained at the outer diameter of the pipe 0.0127m, the arrangement of pipes 45o, the distance between the pipes is 1.25 and the length of the pipe 1.2 m. This heat exchanger has a maximum heat transfer capacity of 64.8 kW with a water mass flow rate of 0.1761 kg/second, an average temperature difference of LMTD 109.3 oK and has an effectiveness of 26.41 %. Thermal validation of manual and CFD calculation results did not show a significant difference. Manual calculation of water output temperature is in the range of 80.5 oC and the result of CFD 76 oC and exhaust gas calculation is 110 oC and CFD 114 oC.

Keywords:

0
2021
Author:  
Citation Owners
Information: There is no ciation to this publication.
Similar Articles








Natural Volatiles and Essential Oils

Field :   Fen Bilimleri ve Matematik; Sağlık Bilimleri

Journal Type :   Uluslararası

Metrics
Article : 2.892
Cite : 271
2023 Impact : 0.316
Natural Volatiles and Essential Oils