User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 18
 Downloands 1
Quantification of transformation products of unsymmetrical dimethylhydrazine in aqueous extracts from soil based on vacuum-assisted headspace solid-phase microextraction
2018
Journal:  
Chemical Bulletin of Kazakh National University
Author:  
DOI:  
10.15328/cb1014
Abstract:

Quantification of transformation products of unsymmetrical dimethylhydrazine (UDMH) in soil requires tedious, time- and labor-consuming sample preparation. The simple and fast method for quantification of transformation products of UDMH in aqueous extracts from soil using vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) was optimized in this work. The method is based on extraction of analytes from soil with water followed by Vac-HSSPME of the obtained aqueous extracts, and gas chromatography-mass spectrometry analysis. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. The effect of a sample pH on responses of target analytes was studied. It was negligible, and no pH adjustment was recommended before a subsequent extraction. The water amount was optimized to provide the best combination of analytes responses and their precision. Extraction by adding 7.00 mL of water to 2.0 g of soil ensured linear dependence of responses of the analytes on their concentrations in soil. The optimized method provided detection limits of target analytes in soil in the range from 0.2 to 9 ng/g. The spike recoveries obtained for model samples were in the range 90-103%. The developed method can be recommended for application in laboratories conducting routine analyses of soil samples potentially contaminated by rocket fuel residuals.

Keywords:

0
2018
Author:  
DOI:  
10.15328/cb1014
Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Chemical Bulletin of Kazakh National University

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 668
Cite : 8
Chemical Bulletin of Kazakh National University