User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 6
Medikal Metroloji için Meme Dokusuna Dielektrik Özelliği Eş Jel Fantom Üretimi ve SiC Nanotozlarının Dielektrik Sabitine Etkisi
2019
Journal:  
Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Author:  
Abstract:

Gelişen teknoloji ile üretilen medikal cihazların hem görüntü kalitesini arttırmak hem de kalibrasyon ayarları için önemli bir yeri olan fantomların büyük eksikleri bulunmaktadır. Bu eksikliklerden en önemlileri fantomu oluşturan yapıların konsantrasyonunun zamanla değişmesi ve dış etkenlere bağlı olarak yapının bozulmasıdır. Bu olumsuz etkilere karşı daha uzun süre dayanıklı olan ve canlı doku özelliğine yakın elektriksel özellikler gösteren jel fantomlar tasarlamak ve geliştirmek önemlidir. Birçok alanda olduğu gibi medikal alanda da canlı insan deneklerin kullanılması sağlığa zararlı olma ihtimalinden dolayı birçok etik kurul tarafından uygun görülmemiştir ve yasaklanmıştır. Canlı insan deneklerin yerine yakın özelliklere sahip fantomlar kullanılmaktadır. Bu fantomların MR, Ultrason, Tomografi, Röntgen gibi görüntüleme sistemlerinde elektriksel özelliklerini kaybettiği çalışma aralığının belirlenmesi gerekir. Buna ek olarak mobil telefonların yaygın olarak kullanıldığı günümüzde bu cihazlardan yayılan elektromanyetik ışınların emilimi (SAR) sonucu fantomun elektriksel özelliğini kaybederek bozulma aralığının saptanması gelecekte medikal alanda yapılacak ilerlemeler ve yenilikler için önemlidir. Yapılan çalışmada 5 g PVA, içerisinde 45 ml saf su bulunan bir beherde karıştırma işlemi ile beraber 80oC sıcaklıkta 5 dakika ısıtıldı ve % 10’luk tampon PVA çözeltisi hazırlandı. Bu tampon çözeltilere farklı miktarlarda Triton X-100 maddeleri eklenerek 15 dakika karıştırıldı. 24 saat beklendikten sonra oda sıcaklığında jel fantomların dielektrik sabitlerine bakıldı. Dielektrik sabitinin ölçümü için Agilent 85070E Network Analiz Cihazı ve Performance Probe ile Short Block kullanıldı. 0 ile 20 GHz frekans aralığında alınan ölçümlere göre insan meme dokusunun dielektrik özelliklerini gösteren jel fantomlar elde edildi. Bu jel fantomlardan 10 ml %10’luk PVA+ 5 ml Triton X-100 jel fantomuna 0,1 gr SiC nanotozu karıştırılarak dielektrik sabitindeki değişim incelendi. Daha sonra elde edilen bu jel fantomun WETSEM (Islak Taramalı Elektron Mikroskobu) ile görüntüleri incelendi.  

Keywords:

Development Of Gel Phantom Having Dielectric Property Equal To Breast Tissue For Medical Metrology and The Effect Of Sic Nanopowders On The Dielectric Constant
2019
Author:  
Abstract:

There are major shortcomings of phantoms, which are important for improving the image quality of medical devices produced by developing technology and also for calibration settings. The most important of these shortcomings is the change in the concentration of the structures forming the phantom and the deterioration of the structure due to external factors. It is important to design and develop gel phantoms which are longer time resistant to these negative effects and show electrical properties close to the living tissue.  As is the case in many areas, the use of live human subjects in the medical field has not been approved and banned by many ethics committees due to the possibility of being harmful to health, and instead of living human subjects, phantoms with close features are used. In imaging systems, such as MR, Ultrasound, Tomography, X-ray, the working range of these phantoms should be determined. In addition, the use of mobile telephones has been widely used today, the absorption of electromagnetic rays emitted from these devices (SAR) as a result of the loss of the electrical property of phantom to determine the interval of distortion is important for future advances and innovations in the medical field. In the study, 5 g PVA was heated in a beaker containing 45 ml of pure water for 5 minutes at 80oC with stirring and a 10% buffer PVA solution was prepared. Different amounts of Triton X-100 were added to these buffer solutions and mixed for 15 minutes. After waiting for 24 hours, dielectric constants of gel phantoms were examined at room temperature. Agilent 85070E Network Analyzer and Performance Probe with Short Block were used to measure the dielectric constant. Gel phantoms were obtained showing the dielectric properties of human breast tissue according to the measurements taken in the frequency range 0 to 20 GHz. 10 ml 10% PVA + 5 ml Triton X-100 gel phantom from this gel phantom was examined by changing the dielectric constant by mixing 0.1 g SiC nanopowder. Afterwards, images of this gel phantom obtained with WETSEM (Wet Scanning Electron Microscope) were examined.

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 829
Cite : 1.110
2023 Impact : 0.011
Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi