User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 10
 Downloands 3
Relationship between Gastric pH Measurement and Intra-abdominal Pressure in Patients Undergoing Laparoscopic Surgery
2020
Journal:  
Şişli Etfal Hastanesi Tıp Bülteni
Author:  
Abstract:

Objective: Laparoscopic surgery (LS) is a safe and widely used technique. During LS, carbon dioxide insufflation may produce significant hemodynamic and ventilatory consequences, such as elevated intra-abdominal pressure (IAP) and hypercarbia. Splanchnic and cardiovascular blood flow can be affected by the elevated IAP, which can result in ischemia in the splanchnic region prior to hemodynamic changes. Changes in gastric pH may be an early precursor of changes in splanchnic blood circulation. This study investigated the relationship between gastric pH measurement and IAP in patients undergoing LS. Materials & Methods: This study included 49 patients aged 18 – 65 years with American Society of Anesthesiologists (ASA) physical status I – III who were undergoing elective laparoscopic cholecystectomy. A gastric pH tonometer probe was applied using an orogastric catheter. Simultaneously, insufflation pressure, cardiac apex beat (CAB), and mean arterial blood pressure (MAP) values were recorded. Indirect IAP was then measured through the bladder. Measurements were performed at baseline; at 15, 30, and 60 minutes after onset of insufflation (AI 15, AI 30, and AI 60, respectively); and at the end of insufflation (EI). Two pH measurements were obtained with a gastric tonometer pH probe, using an automated function of the gastric tonometer to improve measurement reliability. Results: IAP was significantly higher than baseline at AI 15, AI 30, AI 60, and EI (p < 0.001). The pH1 and pH2 levels were significantly lower at AI 15 and AI 30, compared with baseline (p < 0.001). There were no significant differences between pH1 and pH2 measurements at AI 60 and EI. Compared with baseline, CAB was significantly lower at AI 15, AI 30, AI 60, and EI (p = 0.001, p < 0.001, p = 0.006). There were no statistically significant differences in MAP changes at any time point. Conclusion: Elevated IAP caused by CO2 insufflation during LS led to reductions of pH1 and pH2. There was a correlation between gastric pH measurement and IAP. Measurement of gastric pH may be useful to assess blood circulation in the splenic area during LS. (SETB-2020-06-107)

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Şişli Etfal Hastanesi Tıp Bülteni

Field :   Sağlık Bilimleri

Journal Type :   Ulusal

Metrics
Article : 901
Cite : 1.228
2023 Impact : 0.019
Şişli Etfal Hastanesi Tıp Bülteni