User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 15
 Downloands 4
Characteristics research of low-temperature heat pipes for energy-saving equipment
2016
Journal:  
Technology Audit and Production Reserves
Author:  
Abstract:

The efficiency of the heat pipes (HP) is largely dependent on the characteristics of capillary structures (CS) used therein. Due to the composite materials developed in Institute for Problems in Materials Science (IPMS) of NAS of Ukraine, which were used as the CS, Ukrainian heat pipes with high hydrodynamic and thermal characteristics were developed. The aim of the experimental work of the authors was the comparison of thermal characteristics of heat pipes that are based on composite porous structures with similar HP characteristics with fiber porous structures (which are considered to be the most effective view of insert HP). The results showed that HP with composite CS provides better thermal characteristics, especially when the heating of pipes was from the top, and cooling – from the bottom. In this position, a composite HP with CS steadily functioned under heat load up to 25 watts, whereas HP with fiber CS stopped stable operation at a load of 15 watts. As with the horizontal and vertical arrangement of the pipe (at «below» heat input), the value of thermal resistance (R [K/W]) for pipes with composite CS did not exceed values R that are typical for HP with fiber porous structures. Thus, thanks to the authors, it was found that the new composite structure is more appropriate to use when placing the HP at an angle to the "upper" heat supply than fiber HP. Author Biographies Андрей Андреевич Шаповал, National Technical University of Ukraine «Kyiv Polytechnic Institute», 37 Peremohu avenue, Kiev, Ukraine, 03056 Candidate of Technical Science, Associate Professor, Senior Research Fellow Department of Chemical Engineering

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Technology Audit and Production Reserves

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 2.454
Cite : 270
2023 Impact : 0.047
Technology Audit and Production Reserves