User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 21
 Downloands 1
N,N`-Bis(1`-hydroxy-2`-acetonaphthone)propylenediamine: Synthesis, Extractive Properties, and Use as an Ionophore in a Cu(II)-Selective Potentiometric Sensor
2007
Journal:  
Turkish Journal of Chemistry
Author:  
Abstract:

The binding ability of N,N'-bis(1'-hydroxy-2'-acetonaphthone)propylenediimine (H2L) towards metal ions was investigated by performing liquid-liquid extraction experiments to extract Cu2+, Ni2+, Co2+, and Zn2+ ions from nitrate solutions. Extraction takes place by a cation exchange mechanism and the ligand shows a pronounced selectivity towards Cu2+ ions. Conventional log-log analysis of the extraction data reveals that the Cu2+ ions are extracted by a 1:1 (metal to ligand) complex formation. The effect of parameters influencing the extraction process, such as type of diluent and concentration of electrolyte in the aqueous phase, has been studied. The selectivity of the ligand was evaluated by competitive extraction of copper ions from a synthetic sample. The selective extraction of copper ions allows the use of H2L as an ion-sensing material for fabricating a Cu(II)-ion-selective electrode. This sensor gave a good Nernstian response of 29.7 \pm 0.3 mV/decade over a concentration range of 10-4-10-1 M of copper ions, independent of pH in the range of 3.5-6.5, with a detection limit of 2 \times 10-5 M and a response time of < 20 s. The electrode was used as a potentiometric indicator for the complexometric titration of a copper solution with a standard solution of EDTA

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










Turkish Journal of Chemistry

Field :   Fen Bilimleri ve Matematik

Journal Type :   Uluslararası

Metrics
Article : 2.410
Cite : 1.692
2023 Impact : 0.068
Turkish Journal of Chemistry