User Guide
Why can I only view 3 results?
You can also view all results when you are connected from the network of member institutions only. For non-member institutions, we are opening a 1-month free trial version if institution officials apply.
So many results that aren't mine?
References in many bibliographies are sometimes referred to as "Surname, I", so the citations of academics whose Surname and initials are the same may occasionally interfere. This problem is often the case with citation indexes all over the world.
How can I see only citations to my article?
After searching the name of your article, you can see the references to the article you selected as soon as you click on the details section.
 Views 28
 Downloands 3
The development of simultaneous transducer ultrasonic with dual-transducer to measure flow velocity in the pipe
2023
Journal:  
EUREKA: Physics and Engineering
Author:  
Abstract:

There are still several obstacles to calculating fluid flow rate measurement on custody transfer, such as the distribution of one-phase fluid flow rate, less sTable pressure, and fluid flow rate changes, which are still the main problems in the process of a measuring system. To calculate the flow rate of one phase fluid, there is a method often used, namely transit time. In practice, the transit time works to send the ultrasonic pulse from upstream to downstream, which had to have a delay because the transducer must switch the function of a transducer to become transmitter or receiver. So, this paper proposed a new strategy of measurement multipath ultrasonic flowmeter (UFLW) with a simultaneous transit time method using a dual transmitter and receiver. The simultaneous method is a measuring technique that utilizes a pair of ultrasonic transducers as both trigger and receiver. The first transducer serves as the transmitter, while the second functions as the receiver, capturing the signal at the same time without changing their positions or roles. In order to implement the configuration setup, let’s try to use 3 paths configuration with 6 pairs of transducers, 3 on the upstream and 3 on the downstream. To estimate the flow velocity, let’s use long short-term memory (LSTM), which is one of the recurrent neural networks (RNN) architectures in the deep learning algorithm, and to evaluate the performance, let’s use the Bland-Altman plot and root mean squared error (RMSE) and validation loss of the LSTM model. The result shows RMSE 0.289 from the actual flow velocity, which means an LTSM with simultaneous multipath ultrasonic can reduce the error between prediction and actual measurement

Keywords:

Citation Owners
Information: There is no ciation to this publication.
Similar Articles










EUREKA: Physics and Engineering

Field :   Mühendislik

Journal Type :   Uluslararası

Metrics
Article : 490
Cite : 293
2023 Impact : 0.242
EUREKA: Physics and Engineering